HL7 Terminology (THO)
3.1.0 - Publication
This page is part of the HL7 Terminology (v3.1.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions
Active as of 2019-12-01 |
{
"resourceType" : "CodeSystem",
"id" : "v2-0365",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Properties</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>URL</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>code</td><td>Status of the concept</td></tr><tr><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>code</td><td>Version of HL7 in which the code was deprecated</td></tr></table><p>This code system http://terminology.hl7.org/CodeSystem/v2-0365 defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>deprecated</b></td></tr><tr><td style=\"white-space:nowrap\">IN<a name=\"v2-0365-IN\"> </a></td><td>Initializing</td><td>Software is ready, hardware not yet</td><td/></tr><tr><td style=\"white-space:nowrap\">CO<a name=\"v2-0365-CO\"> </a></td><td>Configuring</td><td>Configuring</td><td/></tr><tr><td style=\"white-space:nowrap\">PU<a name=\"v2-0365-PU\"> </a></td><td>Powered Up</td><td>Software and hardware are not yet ready</td><td/></tr><tr><td style=\"white-space:nowrap\">RS<a name=\"v2-0365-RS\"> </a></td><td>Ready to start</td><td>Software and hardware are ready, but user action is required to start</td><td/></tr><tr><td style=\"white-space:nowrap\">ID<a name=\"v2-0365-ID\"> </a></td><td>Idle</td><td>Successfully started, new orders can be accepted, currently no orders are present</td><td/></tr><tr><td style=\"white-space:nowrap\">OP<a name=\"v2-0365-OP\"> </a></td><td>Normal Operation</td><td>Successfully started, new orders can be accepted</td><td/></tr><tr><td style=\"white-space:nowrap\">CL<a name=\"v2-0365-CL\"> </a></td><td>Clearing</td><td>Clearing</td><td/></tr><tr><td style=\"white-space:nowrap\">PA<a name=\"v2-0365-PA\"> </a></td><td>Pausing</td><td>Pausing</td><td/></tr><tr><td style=\"white-space:nowrap\">PD<a name=\"v2-0365-PD\"> </a></td><td>Paused</td><td>User action is required to continue</td><td/></tr><tr><td style=\"white-space:nowrap\">ES<a name=\"v2-0365-ES\"> </a></td><td>E-stopped</td><td>Error, remaining orders can be finished, new orders cannot be accepted</td><td/></tr><tr><td style=\"white-space:nowrap\">…<a name=\"v2-0365-.8230\"> </a></td><td>(null) No state change</td><td>(null) No state change</td><td>2.9</td></tr><tr><td style=\"white-space:nowrap\">TS<a name=\"v2-0365-TS\"> </a></td><td>Transport stopped</td><td>Transport stopped</td><td/></tr><tr><td style=\"white-space:nowrap\">SS<a name=\"v2-0365-SS\"> </a></td><td>Sampling stopped</td><td>Sampling stopped</td><td/></tr><tr><td style=\"white-space:nowrap\">SD<a name=\"v2-0365-SD\"> </a></td><td>Shutting down</td><td>Shutting down</td><td/></tr><tr><td style=\"white-space:nowrap\">DI<a name=\"v2-0365-DI\"> </a></td><td>Diagnose</td><td>Diagnose</td><td/></tr><tr><td style=\"white-space:nowrap\">...<a name=\"v2-0365-.46.46.46\"> </a></td><td>(null) No state change</td><td>(null) No state change</td><td>2.9</td></tr><tr><td style=\"white-space:nowrap\">MA<a name=\"v2-0365-MA\"> </a></td><td>Maintenance</td><td>Maintenance</td><td/></tr><tr><td style=\"white-space:nowrap\">FL<a name=\"v2-0365-FL\"> </a></td><td>Failure</td><td>Failure, remaining orders are aborted, new orders cannot be accepted</td><td/></tr><tr><td style=\"white-space:nowrap\">UNK<a name=\"v2-0365-UNK\"> </a></td><td>Unknown</td><td>Unknown</td><td/></tr><tr><td style=\"white-space:nowrap\">LT<a name=\"v2-0365-LT\"> </a></td><td>Limited test menu</td><td>For diagnostic instruments: some test types are unavailable</td><td/></tr></table></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "oo"
}
],
"url" : "http://terminology.hl7.org/CodeSystem/v2-0365",
"identifier" : [
{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.18.223"
}
],
"version" : "2.3.0",
"name" : "EquipmentState",
"title" : "equipmentState",
"status" : "active",
"experimental" : false,
"date" : "2019-12-01",
"publisher" : "HL7, Inc",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/"
}
]
}
],
"description" : "HL7-defined code system of concepts that identify the status the equipment was in at the time the transaction was initiated. Used in HL7 Version 2.x messaging in the EQU segment.",
"purpose" : "Underlying Master Code System for V2 table 0365 (Equipment State)",
"copyright" : "Copyright HL7. Licensed under creative commons public domain",
"caseSensitive" : true,
"valueSet" : "http://terminology.hl7.org/ValueSet/v2-0365",
"hierarchyMeaning" : "is-a",
"compositional" : false,
"versionNeeded" : false,
"content" : "complete",
"property" : [
{
"code" : "status",
"uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status",
"description" : "Status of the concept",
"type" : "code"
},
{
"code" : "deprecated",
"uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated",
"description" : "Version of HL7 in which the code was deprecated",
"type" : "code"
}
],
"concept" : [
{
"id" : "3663",
"code" : "IN",
"display" : "Initializing",
"definition" : "Software is ready, hardware not yet",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3664",
"code" : "CO",
"display" : "Configuring",
"definition" : "Configuring",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3665",
"code" : "PU",
"display" : "Powered Up",
"definition" : "Software and hardware are not yet ready",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3666",
"code" : "RS",
"display" : "Ready to start",
"definition" : "Software and hardware are ready, but user action is required to start",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3667",
"code" : "ID",
"display" : "Idle",
"definition" : "Successfully started, new orders can be accepted, currently no orders are present",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3668",
"code" : "OP",
"display" : "Normal Operation",
"definition" : "Successfully started, new orders can be accepted",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3669",
"code" : "CL",
"display" : "Clearing",
"definition" : "Clearing",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3670",
"code" : "PA",
"display" : "Pausing",
"definition" : "Pausing",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3671",
"code" : "PD",
"display" : "Paused",
"definition" : "User action is required to continue",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3672",
"code" : "ES",
"display" : "E-stopped",
"definition" : "Error, remaining orders can be finished, new orders cannot be accepted",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3673",
"code" : "…",
"display" : "(null) No state change",
"definition" : "(null) No state change",
"property" : [
{
"code" : "deprecated",
"valueCode" : "2.9"
},
{
"code" : "status",
"valueCode" : "D"
}
]
},
{
"id" : "3674",
"code" : "TS",
"display" : "Transport stopped",
"definition" : "Transport stopped",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3675",
"code" : "SS",
"display" : "Sampling stopped",
"definition" : "Sampling stopped",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3676",
"code" : "SD",
"display" : "Shutting down",
"definition" : "Shutting down",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3677",
"code" : "DI",
"display" : "Diagnose",
"definition" : "Diagnose",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3678",
"code" : "...",
"display" : "(null) No state change",
"definition" : "(null) No state change",
"property" : [
{
"code" : "deprecated",
"valueCode" : "2.9"
},
{
"code" : "status",
"valueCode" : "D"
}
]
},
{
"id" : "3679",
"code" : "MA",
"display" : "Maintenance",
"definition" : "Maintenance",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3680",
"code" : "FL",
"display" : "Failure",
"definition" : "Failure, remaining orders are aborted, new orders cannot be accepted",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3681",
"code" : "UNK",
"display" : "Unknown",
"definition" : "Unknown",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3682",
"code" : "LT",
"display" : "Limited test menu",
"definition" : "For diagnostic instruments: some test types are unavailable",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
}
]
}