HL7 Terminology (THO)
3.0.0 - Publication

This page is part of the HL7 Terminology (v3.0.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions

ValueSet: ObservationInterpretationDetected

Summary

Defining URL:http://terminology.hl7.org/ValueSet/v3-ObservationInterpretationDetected
Version:2.0.0
Name:ObservationInterpretationDetected
Status:Active as of 3/26/14
Definition:

Interpretations of the presence or absence of a component / analyte or organism in a test or of a sign in a clinical observation. In keeping with laboratory data processing practice, these concepts provide a categorical interpretation of the "meaning" of the quantitative value for the same observation.

OID:2.16.840.1.113883.1.11.20328 (for OID based terminology systems)
Source Resource:XML / JSON / Turtle

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

 

Expansion

This value set contains 6 concepts

Expansion based on ObservationInterpretation v2.0.0 (CodeSystem)

All codes in this table are from the system http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation

LvlCodeDisplayDefinition
0ObservationInterpretationDetectionObservationInterpretationDetectionInterpretations of the presence or absence of a component / analyte or organism in a test or of a sign in a clinical observation. In keeping with laboratory data processing practice, these concepts provide a categorical interpretation of the "meaning" of the quantitative value for the same observation.
1  INDIndeterminateThe specified component / analyte, organism or clinical sign could neither be declared positive / negative nor detected / not detected by the performed test or procedure. *Usage Note:* For example, if the specimen was degraded, poorly processed, or was missing the required anatomic structures, then "indeterminate" (i.e. "cannot be determined") is the appropriate response, not "equivocal".
2    EEquivocalThe test or procedure was successfully performed, but the results are borderline and can neither be declared positive / negative nor detected / not detected according to the current established criteria.
1  NEGNegativeAn absence finding of the specified component / analyte, organism or clinical sign based on the established threshold of the performed test or procedure. \[Note: Negative does not necessarily imply the complete absence of the specified item.\]
2    NDNot detectedThe presence of the specified component / analyte, organism or clinical sign could not be determined within the limit of detection of the performed test or procedure.
1  POSPositiveA presence finding of the specified component / analyte, organism or clinical sign based on the established threshold of the performed test or procedure.
2    DETDetectedThe measurement of the specified component / analyte, organism or clinical sign above the limit of detection of the performed test or procedure.

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
Source The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code

History

DateActionAuthorCustodianComment
2020-05-06reviseTed KleinVocabulary WGMigrated to the UTG maintenance environment and publishing tooling.
2014-03-26reviseVocabulary (Woody Beeler) (no record of original request)2014T1_2014-03-26_001283 (RIM release ID)Lock all vaue sets untouched since 2014-03-26 to trackingId 2014T1_2014_03_26