HL7 Terminology (THO)
3.0.0 - Publication

This page is part of the HL7 Terminology (v3.0.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions

CodeSystem: reasonForStudy

Summary

Defining URL:http://terminology.hl7.org/CodeSystem/v2-0951
Version:2.1.0
Name:ReasonForStudy
Status:Active as of 12/1/19
Definition:

HL7-defined code system of concepts that provide additional information to the universal service identifier on why a test, study or review was ordered. Initial values are to support the IHE LCC LAB-7 transaction.

Publisher:HL7, Inc
Committee:Orders and Observations
Copyright:

Copyright HL7. Licensed under creative commons public domain

Content:Complete: All the concepts defined by the code system are included in the code system resource
OID:2.16.840.1.113883.18.451 (for OID based terminology systems)
Value Set:http://terminology.hl7.org/ValueSet/v2-0951 ( is the value set for all codes in this code system)
Source Resource:XML / JSON / Turtle

This Code system is referenced in the content logical definition of the following value sets:

Properties

CodeURLDescriptionType
statushttp://terminology.hl7.org/CodeSystem/utg-concept-properties#statusStatus of the conceptcode
deprecatedhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecatedVersion of HL7 in which the code was deprecatedcode
v2-concCommenthttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentV2 Concept Commentstring
HL7usageNoteshttp://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotesHL7 Concept Usage Notesstring

This code system http://terminology.hl7.org/CodeSystem/v2-0951 defines the following codes:

CodeDisplayDefinitionV2 Concept CommentHL7 Concept Usage Notes
BS Bank residual specimenRequests that the specimen should be stored long term
CR Confirm results valueRequests verification of previously reported resultsUsed to indicate why review is requested
FP Store residual specimen pending follow upRequests that the specimen should be saved for a short duration until follow up is completedProvides instructions for Specimen storage
IN Interpret resultsRequests interpretation of previously reported resultsUsed to indicate why review is requested
IR Review clinically inconsistent resultsRequests comparison of previously reported results amongst themselvesUsed to indicate why review is requested
IT Incorrect test performedFor process improvement work this code can be used to identify when an incorrect test was performed for the target orderUsed to indicate why review is requested
OP Test ordering problemFor process improvement work this code can be used to identify orders and the respective results, where problems occurred during orderingUsed to indicate why review is requested
PI Patient identification problemFor process improvement work this code can be used to identify when a patient identification issue has occurred on the target orderUsed to indicate why review is requested
SI Suspected interferenceRequests verification of previously reported results due to suspected interferenceUsed to indicate why review is requested
SP Sampling problemFor process improvement work this code can be used to identify orders, where problems occurred during sample collectionUsed to indicate why review is requested
TP Specimen transport problemFor process improvement work this code can be used to identify orders, where problems occurred during sample transportUsed to indicate why review is requested
TT Turnaround time problemFor process improvement work this code can be used to identify results with excessive reporting delayUsed to indicate why review is requested
XR Incorrect resultsFor process improvement work this code can be used to identify when incorrect result were reported for the target orderUsed to indicate why review is requested