Generated Narrative: CodeSystem v3-AcknowledgementDetailCode

Language: en

Properties

This code system defines the following properties for its concepts

NameCodeURITypeDescription
SpecializesSpecializesCodingThe child code is a more narrow version of the concept represented by the parent code. I.e. Every child concept is also a valid parent concept. Used to allow determination of subsumption. Must be transitive, irreflexive, antisymmetric.
GeneralizesGeneralizesCodingInverse of Specializes. Only included as a derived relationship.
internalIdinternalIdhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v3-internal-idcodeThe internal identifier for the concept in the HL7 Access database repository.
Statusstatushttp://hl7.org/fhir/concept-properties#statuscodeDesignation of a concept's state. Normally is not populated unless the state is retired..
Not SelectablenotSelectablehttp://hl7.org/fhir/concept-properties#notSelectablebooleanIndicates that the code is abstract - only intended to be used as a selector for other concepts

Concepts

This case-sensitive code system http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode defines the following codes in a Is-A hierarchy:

LvlCodeDisplayDefinitioninternalIdStatusNot Selectable
1_AcknowledgementDetailNotSupportedCode AcknowledgementDetailNotSupportedCodeRefelects rejections because elements of the communication are not supported in the current context.21419activetrue
2  NS200 Unsupported interactionThe interaction (or: this version of the interaction) is not supported.21420active
2  NS202 Unsupported processing idThe Processing ID is not supported.21421active
2  NS203 Unsupported version idThe Version ID is not supported.21423active
2  NS250 Unsupported processing ModeThe processing mode is not supported.21422active
2  NS260 Unknown senderThe Device.id of the sender is unknown.21424active
2  NS261 Unrecognized attentionlineThe receiver requires information in the attentionLine classes for routing purposes.21425active
1INTERR Internal system errorAn internal software component (database, application, queue mechanism, etc.) has failed, leading to inability to process the message.22074active
1NOSTORE No storage space for message.**Rejection:** The message can't be stored by the receiver due to an unspecified internal application issue. The message was neither processed nor stored by the receiving application.21442active
1RTEDEST Message routing error, destination unreachable.**Error:** The destination of this message is known to the receiving application. Messages have been successfully routed to that destination in the past. The link to the destination application or an intermediate application is unavailable.21443active
1RTUDEST Error: Message routing error, unknown destination.The destination of this message is unknown to the receiving application. The receiving application in the message does not match the application which received the message. The message was neither routed, processed nor stored by the receiving application.21440active
1RTWDEST Message routing warning, destination unreachable.**Warning:** The destination of this message is known to the receiving application. Messages have been successfully routed to that destination in the past. The link to the destination application or an intermediate application is (temporarily) unavailable. The receiving application will forward the message as soon as the destination can be reached again.21441active
1SYN Syntax errorReflects errors in the syntax or structure of the communication.22075active
2  SYN102 Data type errorThe attribute contained data of the wrong data type, e.g. a numeric attribute contained "FOO".21414active
2  SYN105 Required element missing**Description:** Required association or attribute missing in message; or the sequence of the classes is different than required by the standard or one of the conformance profiles identified in the message.22747active
3    SYN100 Required association missingRequired association missing in message; or the sequence of the classes is different than required by the standard or one of the conformance profiles identified in the message.21412active
3    SYN101 Required attribute missingA required attribute is missing in a class.21413active
3    SYN114 Insufficient repetitions**Description:** The number of repetitions of a group of association or attributes is less than the required minimum for the standard or of one of the conformance profiles or templates identified in the message.22748active
2  SYN106 Terminology error**Description:** A coded attribute or datatype property violates one of the terminology constraints specified in the standard or one of the conformance profiles or templates declared by the instance.22749active
3    SYN103 Value not found in code systemAn attribute value was compared against the corresponding code system, and no match was found.21415active
3    SYN104 Invalid code system in CNEAn attribute value referenced a code system that is not valid for an attribute constrained to CNE.21416active
3    SYN107 Deprecated code**Description:** A coded attribute is referencing a code that has been deprecated by the owning code system.22750active
2  SYN108 Number of repetitions exceeds limit**Description:** The number of repetitions of a (group of) association(s) or attribute(s) exceeds the limits of the standard or of one of the conformance profiles or templates identified in the message.22751active
3    SYN110 Number of association repetitions exceeds limitThe number of repetitions of a (group of) association(s) exceeds the limits of the standard or of one of the conformance profiles identified in the message.21417active
3    SYN112 Number of attribute repetitions exceeds limitThe number of repetitions of an attribute exceeds the limits of the standard or of one of the conformance profiles identified in the message.21418active
2  SYN109 Mandatory element with null value**Description:** An attribute or association identified as mandatory in a specification or declared conformance profile or template has been specified with a null flavor.22752active
2  SYN111 Value does not match fixed value**Description:** The value of an attribute or property differs from the fixed value asserted in the standard or one of the conformance profiles or templates declared in the message.22753active
2  SYN113 Formal constraint violation**Description:** A formal constraint asserted in the standard or one of the conformance profiles or templates declared in the message has been violated.22754active
1_AcknowledgementDetailSyntaxErrorCode AcknowledgementDetailSyntaxErrorCodeReflects errors in the syntax or structure of the communication.21411retiredtrue
<status value="active"/> <experimental value="false"/> <date value="2019-03-20"/> <publisher value="Health Level Seven International"/> <contact> <telecom> <system value="url"/> <value value="http://hl7.org"/> </telecom> <telecom> <system value="email"/> <value value="hq@HL7.org"/> </telecom> </contact> <description value="*OpenIssue:*Missing description."/> <copyright value="This material derives from the HL7 Terminology THO. THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html"/> <caseSensitive value="true"/> <hierarchyMeaning value="is-a"/> <content value="complete"/> <property> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-symmetry"> <valueCode value="antisymmetric"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-transitivity"> <valueCode value="transitive"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-reflexivity"> <valueCode value="irreflexive"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-isNavigable"> <valueBoolean value="true"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-relationshipKind"> <valueCode value="Specializes"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-inverseName"> <valueString value="Generalizes"/> </extension> <code value="Specializes"/> <description value="The child code is a more narrow version of the concept represented by the parent code. I.e. Every child concept is also a valid parent concept. Used to allow determination of subsumption. Must be transitive, irreflexive, antisymmetric."/> <type value="Coding"/> </property> <property> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-symmetry"> <valueCode value="antisymmetric"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-transitivity"> <valueCode value="transitive"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-reflexivity"> <valueCode value="irreflexive"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-isNavigable"> <valueBoolean value="true"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-relationshipKind"> <valueCode value="Generalizes"/> </extension> <extension url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-inverseName"> <valueString value="Specializes"/> </extension> <code value="Generalizes"/> <description value="Inverse of Specializes. Only included as a derived relationship."/> <type value="Coding"/> </property> <property> <code value="internalId"/> <uri value="http://terminology.hl7.org/CodeSystem/utg-concept-properties#v3-internal-id"/> <description value="The internal identifier for the concept in the HL7 Access database repository."/> <type value="code"/> </property> <property> <code value="status"/> <uri value="http://hl7.org/fhir/concept-properties#status"/> <description value="Designation of a concept's state. Normally is not populated unless the state is retired.."/> <type value="code"/> </property> <property> <code value="notSelectable"/> <uri value="http://hl7.org/fhir/concept-properties#notSelectable"/> <description value="Indicates that the code is abstract - only intended to be used as a selector for other concepts"/> <type value="boolean"/> </property> <concept> <code value="_AcknowledgementDetailNotSupportedCode"/> <display value="AcknowledgementDetailNotSupportedCode"/> <definition value="Refelects rejections because elements of the communication are not supported in the current context."/> <property> <code value="notSelectable"/> <valueBoolean value="true"/> </property> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21419"/> </property> <concept> <code value="NS200"/> <display value="Unsupported interaction"/> <definition value="The interaction (or: this version of the interaction) is not supported."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21420"/> </property> </concept> <concept> <code value="NS202"/> <display value="Unsupported processing id"/> <definition value="The Processing ID is not supported."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21421"/> </property> </concept> <concept> <code value="NS203"/> <display value="Unsupported version id"/> <definition value="The Version ID is not supported."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21423"/> </property> </concept> <concept> <code value="NS250"/> <display value="Unsupported processing Mode"/> <definition value="The processing mode is not supported."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21422"/> </property> </concept> <concept> <code value="NS260"/> <display value="Unknown sender"/> <definition value="The Device.id of the sender is unknown."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21424"/> </property> </concept> <concept> <code value="NS261"/> <display value="Unrecognized attentionline"/> <definition value="The receiver requires information in the attentionLine classes for routing purposes."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21425"/> </property> </concept> </concept> <concept> <code value="INTERR"/> <display value="Internal system error"/> <definition value="An internal software component (database, application, queue mechanism, etc.) has failed, leading to inability to process the message."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22074"/> </property> </concept> <concept> <code value="NOSTORE"/> <display value="No storage space for message."/> <definition value="**Rejection:** The message can't be stored by the receiver due to an unspecified internal application issue. The message was neither processed nor stored by the receiving application."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21442"/> </property> </concept> <concept> <code value="RTEDEST"/> <display value="Message routing error, destination unreachable."/> <definition value="**Error:** The destination of this message is known to the receiving application. Messages have been successfully routed to that destination in the past. The link to the destination application or an intermediate application is unavailable."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21443"/> </property> </concept> <concept> <code value="RTUDEST"/> <display value="Error: Message routing error, unknown destination."/> <definition value="The destination of this message is unknown to the receiving application. The receiving application in the message does not match the application which received the message. The message was neither routed, processed nor stored by the receiving application."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21440"/> </property> </concept> <concept> <code value="RTWDEST"/> <display value="Message routing warning, destination unreachable."/> <definition value="**Warning:** The destination of this message is known to the receiving application. Messages have been successfully routed to that destination in the past. The link to the destination application or an intermediate application is (temporarily) unavailable. The receiving application will forward the message as soon as the destination can be reached again."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21441"/> </property> </concept> <concept> <code value="SYN"/> <display value="Syntax error"/> <definition value="Reflects errors in the syntax or structure of the communication."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22075"/> </property> <concept> <code value="SYN102"/> <display value="Data type error"/> <definition value="The attribute contained data of the wrong data type, e.g. a numeric attribute contained "FOO"."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21414"/> </property> </concept> <concept> <code value="SYN105"/> <display value="Required element missing"/> <definition value="**Description:** Required association or attribute missing in message; or the sequence of the classes is different than required by the standard or one of the conformance profiles identified in the message."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22747"/> </property> <concept> <code value="SYN100"/> <display value="Required association missing"/> <definition value="Required association missing in message; or the sequence of the classes is different than required by the standard or one of the conformance profiles identified in the message."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21412"/> </property> </concept> <concept> <code value="SYN101"/> <display value="Required attribute missing"/> <definition value="A required attribute is missing in a class."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21413"/> </property> </concept> <concept> <code value="SYN114"/> <display value="Insufficient repetitions"/> <definition value="**Description:** The number of repetitions of a group of association or attributes is less than the required minimum for the standard or of one of the conformance profiles or templates identified in the message."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22748"/> </property> </concept> </concept> <concept> <code value="SYN106"/> <display value="Terminology error"/> <definition value="**Description:** A coded attribute or datatype property violates one of the terminology constraints specified in the standard or one of the conformance profiles or templates declared by the instance."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22749"/> </property> <concept> <code value="SYN103"/> <display value="Value not found in code system"/> <definition value="An attribute value was compared against the corresponding code system, and no match was found."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21415"/> </property> </concept> <concept> <code value="SYN104"/> <display value="Invalid code system in CNE"/> <definition value="An attribute value referenced a code system that is not valid for an attribute constrained to CNE."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21416"/> </property> </concept> <concept> <code value="SYN107"/> <display value="Deprecated code"/> <definition value="**Description:** A coded attribute is referencing a code that has been deprecated by the owning code system."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22750"/> </property> </concept> </concept> <concept> <code value="SYN108"/> <display value="Number of repetitions exceeds limit"/> <definition value="**Description:** The number of repetitions of a (group of) association(s) or attribute(s) exceeds the limits of the standard or of one of the conformance profiles or templates identified in the message."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22751"/> </property> <concept> <code value="SYN110"/> <display value="Number of association repetitions exceeds limit"/> <definition value="The number of repetitions of a (group of) association(s) exceeds the limits of the standard or of one of the conformance profiles identified in the message."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21417"/> </property> </concept> <concept> <code value="SYN112"/> <display value="Number of attribute repetitions exceeds limit"/> <definition value="The number of repetitions of an attribute exceeds the limits of the standard or of one of the conformance profiles identified in the message."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="21418"/> </property> </concept> </concept> <concept> <code value="SYN109"/> <display value="Mandatory element with null value"/> <definition value="**Description:** An attribute or association identified as mandatory in a specification or declared conformance profile or template has been specified with a null flavor."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22752"/> </property> </concept> <concept> <code value="SYN111"/> <display value="Value does not match fixed value"/> <definition value="**Description:** The value of an attribute or property differs from the fixed value asserted in the standard or one of the conformance profiles or templates declared in the message."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22753"/> </property> </concept> <concept> <code value="SYN113"/> <display value="Formal constraint violation"/> <definition value="**Description:** A formal constraint asserted in the standard or one of the conformance profiles or templates declared in the message has been violated."/> <property> <code value="status"/> <valueCode value="active"/> </property> <property> <code value="internalId"/> <valueCode value="22754"/> </property> </concept> </concept> <concept> <code value="_AcknowledgementDetailSyntaxErrorCode"/> <display value="AcknowledgementDetailSyntaxErrorCode"/> <definition value="Reflects errors in the syntax or structure of the communication."/> <property> <code value="notSelectable"/> <valueBoolean value="true"/> </property> <property> <code value="status"/> <valueCode value="retired"/> </property> <property> <code value="internalId"/> <valueCode value="21411"/> </property> </concept> </CodeSystem>