HL7 Terminology (THO)
6.1.0 - Publication
This page is part of the HL7 Terminology (v6.1.0: Release) based on FHIR (HL7® FHIR® Standard) v5.0.0. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Official URL: http://terminology.hl7.org/ValueSet/v3-AcknowledgementDetailSyntaxErrorCode | Version: 3.0.0 | |||
Active as of 2014-03-26 | Responsible: Health Level Seven International | Computable Name: AcknowledgementDetailSyntaxErrorCode | ||
Other Identifiers: OID:2.16.840.1.113883.1.11.19639 | ||||
Copyright/Legal: This material derives from the HL7 Terminology THO. THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html |
Reflects errors in the syntax or structure of the communication.
References
Generated Narrative: ValueSet v3-AcknowledgementDetailSyntaxErrorCode
Language: en
http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode
where concept is-a SYN
Generated Narrative: ValueSet
Language: en
Expansion based on codesystem AcknowledgementDetailCode v3.0.0 (CodeSystem)
This value set contains 16 concepts
Level | Code | System | Display | Definition |
1 | SYN | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Syntax error | Reflects errors in the syntax or structure of the communication. |
2 | SYN102 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Data type error | The attribute contained data of the wrong data type, e.g. a numeric attribute contained "FOO". |
2 | SYN105 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Required element missing | Description: Required association or attribute missing in message; or the sequence of the classes is different than required by the standard or one of the conformance profiles identified in the message. |
3 | SYN100 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Required association missing | Required association missing in message; or the sequence of the classes is different than required by the standard or one of the conformance profiles identified in the message. |
3 | SYN101 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Required attribute missing | A required attribute is missing in a class. |
3 | SYN114 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Insufficient repetitions | Description: The number of repetitions of a group of association or attributes is less than the required minimum for the standard or of one of the conformance profiles or templates identified in the message. |
2 | SYN106 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Terminology error | Description: A coded attribute or datatype property violates one of the terminology constraints specified in the standard or one of the conformance profiles or templates declared by the instance. |
3 | SYN103 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Value not found in code system | An attribute value was compared against the corresponding code system, and no match was found. |
3 | SYN104 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Invalid code system in CNE | An attribute value referenced a code system that is not valid for an attribute constrained to CNE. |
3 | SYN107 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Deprecated code | Description: A coded attribute is referencing a code that has been deprecated by the owning code system. |
2 | SYN108 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Number of repetitions exceeds limit | Description: The number of repetitions of a (group of) association(s) or attribute(s) exceeds the limits of the standard or of one of the conformance profiles or templates identified in the message. |
3 | SYN110 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Number of association repetitions exceeds limit | The number of repetitions of a (group of) association(s) exceeds the limits of the standard or of one of the conformance profiles identified in the message. |
3 | SYN112 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Number of attribute repetitions exceeds limit | The number of repetitions of an attribute exceeds the limits of the standard or of one of the conformance profiles identified in the message. |
2 | SYN109 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Mandatory element with null value | Description: An attribute or association identified as mandatory in a specification or declared conformance profile or template has been specified with a null flavor. |
2 | SYN111 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Value does not match fixed value | Description: The value of an attribute or property differs from the fixed value asserted in the standard or one of the conformance profiles or templates declared in the message. |
2 | SYN113 | http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode | Formal constraint violation | Description: A formal constraint asserted in the standard or one of the conformance profiles or templates declared in the message has been violated. |
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |
History
Date | Action | Author | Custodian | Comment |
2023-11-14 | revise | Marc Duteau | TSMG | Add standard copyright and contact to internal content; up-476 |
2022-10-18 | revise | Marc Duteau | TSMG | Fixing missing metadata; up-349 |
2020-05-06 | revise | Ted Klein | Vocabulary WG | Migrated to the UTG maintenance environment and publishing tooling. |
2014-03-26 | revise | Vocabulary (Woody Beeler) (no record of original request) | 2014T1_2014-03-26_001283 (RIM release ID) | Lock all vaue sets untouched since 2014-03-26 to trackingId 2014T1_2014_03_26 |