HL7 Terminology (THO)
5.5.0 - Publication International flag

This page is part of the HL7 Terminology (v5.5.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

ValueSet: ActRelationshipICSRInvestigation

Official URL: http://terminology.hl7.org/ValueSet/v3-ActRelationshipICSRInvestigation Version: 3.0.0
Active as of 2014-03-26 Responsible: Health Level Seven International Computable Name: ActRelationshipICSRInvestigation
Other Identifiers: urn:ietf:rfc:3986#Uniform Resource Identifier (URI)#urn:oid:2.16.840.1.113883.1.11.20353

Copyright/Legal: This material derives from the HL7 Terminology THO. THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license

Description: The ways that product safety Investigations, about which information is captured in an Individual Case Safety Report, are related to each other. One investigation may be performed at a patient care institution, and the second by a manufacturer, a third by a regulatory agency. They may all investigate the same case and are thus related. Other kinds of relationships are replacement (if the mode of the Investigation is changed).

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

  • Include these codes as defined in http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType
    CodeDisplayDefinition
    RPLCreplacesA replacement source act replaces an existing target act. The state of the target act being replaced becomes obselete, but the act is typically still retained in the system for historical reference. The source and target must be of the same type.
    SEQLis sequelAn act relationship indicating that the source act follows the target act. The source act should in principle represent the same kind of act as the target. Source and target need not have the same mood code (mood will often differ). The target of a sequel is called antecedent. Examples for sequel relationships are: revision, transformation, derivation from a prototype (as a specialization is a derivation of a generalization), followup, realization, instantiation.
    SPRThas supportUsed to indicate that an existing service is suggesting evidence for a new observation. The assumption of support is attributed to the same actor who asserts the observation. Source must be an observation, target may be any service (e.g., to indicate a status post).

 

Expansion

Expansion based on codesystem ActRelationshipType v4.0.0 (CodeSystem)

This value set contains 3 concepts.

CodeSystemDisplayDefinition
  RPLChttp://terminology.hl7.org/CodeSystem/v3-ActRelationshipTypereplaces

A replacement source act replaces an existing target act. The state of the target act being replaced becomes obselete, but the act is typically still retained in the system for historical reference. The source and target must be of the same type.

  SEQLhttp://terminology.hl7.org/CodeSystem/v3-ActRelationshipTypeis sequel

An act relationship indicating that the source act follows the target act. The source act should in principle represent the same kind of act as the target. Source and target need not have the same mood code (mood will often differ). The target of a sequel is called antecedent. Examples for sequel relationships are: revision, transformation, derivation from a prototype (as a specialization is a derivation of a generalization), followup, realization, instantiation.

  SPRThttp://terminology.hl7.org/CodeSystem/v3-ActRelationshipTypehas support

Used to indicate that an existing service is suggesting evidence for a new observation. The assumption of support is attributed to the same actor who asserts the observation. Source must be an observation, target may be any service (e.g., to indicate a status post).


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code

History

DateActionAuthorCustodianComment
2023-11-14reviseMarc DuteauTSMGAdd standard copyright and contact to internal content; up-476
2022-10-18reviseMarc DuteauTSMGFixing missing metadata; up-349
2020-05-06reviseTed KleinVocabulary WGMigrated to the UTG maintenance environment and publishing tooling.
2014-03-26reviseVocabulary (Woody Beeler) (no record of original request)2014T1_2014-03-26_001283 (RIM release ID)Lock all vaue sets untouched since 2014-03-26 to trackingId 2014T1_2014_03_26