HL7 Terminology (THO)
5.5.0 - Publication International flag

This page is part of the HL7 Terminology (v5.5.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

ValueSet: ActClassObservationSeries

Official URL: http://terminology.hl7.org/ValueSet/v3-ActClassObservationSeries Version: 3.0.0
Active as of 2014-03-26 Responsible: Health Level Seven International Computable Name: ActClassObservationSeries
Other Identifiers: urn:ietf:rfc:3986#Uniform Resource Identifier (URI)#urn:oid:2.16.840.1.113883.1.11.18875

Copyright/Legal: This material derives from the HL7 Terminology THO. THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license

Container for Correlated Observation Sequences sharing a common frame of reference. All Observations of the same cd must be comparable and relative to the common frame of reference. For example, a 3-channel ECG device records a 12-lead ECG in 4 steps (3 leads at a time). Each of the separate 3-channel recordings would be in their own “OBSCOR”. And, all 4 OBSCOR would be contained in one OBSSER because all the times are relative to the same origin (beginning of the recording) and all the ECG signals were from a fixed set of electrodes.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

 

Expansion

Expansion based on codesystem ActClass v4.0.0 (CodeSystem)

This value set contains 2 concepts.

LevelCodeSystemDisplayDefinition
1  OBSSERhttp://terminology.hl7.org/CodeSystem/v3-ActClassobservation series

Container for Correlated Observation Sequences sharing a common frame of reference. All Observations of the same cd must be comparable and relative to the common frame of reference. For example, a 3-channel ECG device records a 12-lead ECG in 4 steps (3 leads at a time). Each of the separate 3-channel recordings would be in their own "OBSCOR". And, all 4 OBSCOR would be contained in one OBSSER because all the times are relative to the same origin (beginning of the recording) and all the ECG signals were from a fixed set of electrodes.

2    OBSCORhttp://terminology.hl7.org/CodeSystem/v3-ActClasscorrelated observation sequences

Container for Observation Sequences (Observations whose values are contained in LIST<>'s) having values correlated with each other. Each contained Observation Sequence LIST<> must be the same length. Values in the LIST<>'s are correlated based on index. E.g. the values in position 2 in all the LIST<>'s are correlated. This is analogous to a table where each column is an Observation Sequence with a LIST<> of values, and each row in the table is a correlation between the columns. For example, a 12-lead ECG would contain 13 sequences: one sequence for time, and a sequence for each of the 12 leads.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code

History

DateActionCustodianAuthorComment
2023-11-14reviseTSMGMarc DuteauAdd standard copyright and contact to internal content; up-476
2022-10-18reviseTSMGMarc DuteauFixing missing metadata; up-349
2020-05-06reviseVocabulary WGTed KleinMigrated to the UTG maintenance environment and publishing tooling.
2014-03-26revise2014T1_2014-03-26_001283 (RIM release ID)Vocabulary (Woody Beeler) (no record of original request)Lock all vaue sets untouched since 2014-03-26 to trackingId 2014T1_2014_03_26