ValueSet: AcknowledgementDetailSyntaxErrorCode

Official URL: http://terminology.hl7.org/ValueSet/v3-AcknowledgementDetailSyntaxErrorCode Version: 3.0.0
Active as of 2014-03-26 Responsible: Health Level Seven International Computable Name: AcknowledgementDetailSyntaxErrorCode
Other Identifiers: urn:ietf:rfc:3986#Uniform Resource Identifier (URI)#urn:oid:2.16.840.1.113883.1.11.19639

Copyright/Legal: This material derives from the HL7 Terminology THO. THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license

Reflects errors in the syntax or structure of the communication.

References

Logical Definition (CLD)

 

Expansion

Expansion based on codesystem AcknowledgementDetailCode v3.0.0 (CodeSystem)

This value set contains 16 concepts.

LevelCodeSystemDisplayDefinition
1  SYNhttp://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeSyntax error

Reflects errors in the syntax or structure of the communication.

2    SYN102http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeData type error

The attribute contained data of the wrong data type, e.g. a numeric attribute contained "FOO".

2    SYN105http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeRequired element missing

Description: Required association or attribute missing in message; or the sequence of the classes is different than required by the standard or one of the conformance profiles identified in the message.

3      SYN100http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeRequired association missing

Required association missing in message; or the sequence of the classes is different than required by the standard or one of the conformance profiles identified in the message.

3      SYN101http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeRequired attribute missing

A required attribute is missing in a class.

3      SYN114http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeInsufficient repetitions

Description: The number of repetitions of a group of association or attributes is less than the required minimum for the standard or of one of the conformance profiles or templates identified in the message.

2    SYN106http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeTerminology error

Description: A coded attribute or datatype property violates one of the terminology constraints specified in the standard or one of the conformance profiles or templates declared by the instance.

3      SYN103http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeValue not found in code system

An attribute value was compared against the corresponding code system, and no match was found.

3      SYN104http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeInvalid code system in CNE

An attribute value referenced a code system that is not valid for an attribute constrained to CNE.

3      SYN107http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeDeprecated code

Description: A coded attribute is referencing a code that has been deprecated by the owning code system.

2    SYN108http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeNumber of repetitions exceeds limit

Description: The number of repetitions of a (group of) association(s) or attribute(s) exceeds the limits of the standard or of one of the conformance profiles or templates identified in the message.

3      SYN110http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeNumber of association repetitions exceeds limit

The number of repetitions of a (group of) association(s) exceeds the limits of the standard or of one of the conformance profiles identified in the message.

3      SYN112http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeNumber of attribute repetitions exceeds limit

The number of repetitions of an attribute exceeds the limits of the standard or of one of the conformance profiles identified in the message.

2    SYN109http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeMandatory element with null value

Description: An attribute or association identified as mandatory in a specification or declared conformance profile or template has been specified with a null flavor.

2    SYN111http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeValue does not match fixed value

Description: The value of an attribute or property differs from the fixed value asserted in the standard or one of the conformance profiles or templates declared in the message.

2    SYN113http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCodeFormal constraint violation

Description: A formal constraint asserted in the standard or one of the conformance profiles or templates declared in the message has been violated.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code

History

DateActionAuthorCustodianComment
2023-11-14reviseMarc DuteauTSMGAdd standard copyright and contact to internal content; up-476
2022-10-18reviseMarc DuteauTSMGFixing missing metadata; up-349
2020-05-06reviseTed KleinVocabulary WGMigrated to the UTG maintenance environment and publishing tooling.
2014-03-26reviseVocabulary (Woody Beeler) (no record of original request)2014T1_2014-03-26_001283 (RIM release ID)Lock all vaue sets untouched since 2014-03-26 to trackingId 2014T1_2014_03_26