This page is part of the HL7 Terminology (v5.5.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Active as of 2019-12-01 |
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- a fhir:CodeSystem ; fhir:nodeRole fhir:treeRoot ; fhir:id [ fhir:v "v2-0357"] ; # fhir:text [ fhir:status [ fhir:v "generated" ] ; fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Properties</b></p><p><b>This code system defines the following properties for its concepts</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>code</td><td>Status of the concept</td></tr><tr><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>code</td><td>Version of HL7 in which the code was deprecated</td></tr><tr><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>string</td><td>V2 Concept Comment</td></tr><tr><td>v2-concCommentAsPub</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub</td><td>string</td><td>V2 Concept Comment As Published</td></tr></table><p><b>Concepts</b></p><p>This case-sensitive code system <code>http://terminology.hl7.org/CodeSystem/v2-0357</code> defines the following codes in a Is-A heirarchy:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Concept Comment</b></td><td><b>V2 Concept Comment As Published</b></td><td><b>Deutsch (German, de)</b></td></tr><tr><td style=\"white-space:nowrap\">0<a name=\"v2-0357-0\"> </a></td><td>Message accepted</td><td>Message accepted</td><td>Success. Optional, as the AA conveys success. Used for systems that must always return a status code.</td><td>Success. Optional, as the AA conveys success. Used for systems that must always return a status code.</td><td>Nachricht akzeptiert</td></tr><tr><td style=\"white-space:nowrap\">100<a name=\"v2-0357-100\"> </a></td><td>Segment sequence error</td><td>Segment sequence error</td><td>Error: The message segments were not in the proper order, or required segments are missing.</td><td>Error: The message segments were not in the proper order, or required segments are missing.</td><td>Fehler in der Segmentreihenfolge</td></tr><tr><td style=\"white-space:nowrap\">101<a name=\"v2-0357-101\"> </a></td><td>Required field missing</td><td>Required field missing</td><td>Error: A required field is missing from a segment</td><td>Error: A required field is missing from a segment</td><td>erforderliches Feld leer</td></tr><tr><td style=\"white-space:nowrap\">102<a name=\"v2-0357-102\"> </a></td><td>Data type error</td><td>Data type error</td><td>Error: The field contained data of the wrong data type, e.g., an NM field contained "FOO".</td><td>Error: The field contained data of the wrong data type, e.g., an NM field contained "FOO".</td><td>Datentypfehler</td></tr><tr><td style=\"white-space:nowrap\">103<a name=\"v2-0357-103\"> </a></td><td>Table value not found</td><td>Table value not found</td><td>Error: A field of data type ID or IS was compared against the corresponding table, and no match was found.</td><td>Error: A field of data type ID or IS was compared against the corresponding table, and no match was found.</td><td>fehlender Eintrag in der Tabelle</td></tr><tr><td style=\"white-space:nowrap\">104<a name=\"v2-0357-104\"> </a></td><td>Value too long</td><td>Value too long</td><td>Error: a value exceeded the normative length, or the length that the application is able to safely handle.</td><td>Error: a value exceeded the normative length, or the length that the application is able to safely handle.</td><td/></tr><tr><td style=\"white-space:nowrap\">198<a name=\"v2-0357-198\"> </a></td><td>Non-Conformant Cardinality</td><td>An error has been encountered related to HL7 message content. Message is not -conformant with the applicable specification’s (base standard, conformance profile or implementation profile) cardinality.</td><td>Error: Cardinality is listed as [0..3] and more than 3 of the identified element are present in the message.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">199<a name=\"v2-0357-199\"> </a></td><td>Other HL7 Error</td><td>Any other error with the HL7 syntax that is not captured in any of the other error codes in this set.</td><td>Error</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">200<a name=\"v2-0357-200\"> </a></td><td>Unsupported message type</td><td>Unsupported message type</td><td>Rejection: The Message Type is not supported.</td><td>Rejection: The Message Type is not supported.</td><td>Nachrichtentyp wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">201<a name=\"v2-0357-201\"> </a></td><td>Unsupported event code</td><td>Unsupported event code</td><td>Rejection: The Event Code is not supported.</td><td>Rejection: The Event Code is not supported.</td><td>Ereignis wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">202<a name=\"v2-0357-202\"> </a></td><td>Unsupported processing id</td><td>Unsupported processing id</td><td>Rejection: The Processing ID is not supported.</td><td>Rejection: The Processing ID is not supported.</td><td>Processing-ID wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">203<a name=\"v2-0357-203\"> </a></td><td>Unsupported version id</td><td>Unsupported version id</td><td>Rejection: The Version ID is not supported.</td><td>Rejection: The Version ID is not supported.</td><td>Version wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">204<a name=\"v2-0357-204\"> </a></td><td>Unknown key identifier</td><td>Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.</td><td>ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).</td><td>Rejection: The ID of the patient, order, etc., was not found. Used for transactions other than additions, e.g., transfer of a non-existent patient.</td><td>Schlüsselwert nicht gefunden</td></tr><tr><td style=\"white-space:nowrap\">205<a name=\"v2-0357-205\"> </a></td><td>Duplicate key identifier</td><td>Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.</td><td>ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).</td><td>Rejection: The ID of the patient, order, etc., already exists. Used in response to addition transactions (Admit, New Order, etc.).</td><td>doppelter Schlüsselwert</td></tr><tr><td style=\"white-space:nowrap\">206<a name=\"v2-0357-206\"> </a></td><td>Application record locked</td><td>Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.</td><td>ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).</td><td>Rejection: The transaction could not be performed at the application storage level, e.g., database locked.</td><td>Datensatz durch Applikation gesperrt</td></tr><tr><td style=\"white-space:nowrap\">207<a name=\"v2-0357-207\"> </a></td><td>Application error</td><td>An application level error has occurred and the detail for that error is identified in ERR-5.</td><td>This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide.</td><td>Rejection: A catchall for internal errors not explicitly covered by other codes.</td><td>applikationsinterner Fehler</td></tr></table></div>" ] ; # fhir:extension ( [ fhir:url [ fhir:v "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"^^xsd:anyURI ] ; fhir:value [ fhir:v "inm" ] ] ) ; # fhir:url [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0357"^^xsd:anyURI] ; # fhir:identifier ( [ fhir:system [ fhir:v "urn:ietf:rfc:3986"^^xsd:anyURI ] ; fhir:value [ fhir:v "urn:oid:2.16.840.1.113883.18.217" ] ] ) ; # fhir:version [ fhir:v "2.0.0"] ; # fhir:name [ fhir:v "MessageErrorCondition"] ; # fhir:title [ fhir:v "messageErrorCondition"] ; # fhir:status [ fhir:v "active"] ; # fhir:experimental [ fhir:v "false"^^xsd:boolean] ; # fhir:date [ fhir:v "2019-12-01"^^xsd:date] ; # fhir:publisher [ fhir:v "Health Level Seven International"] ; # fhir:contact ( [ ( fhir:telecom [ fhir:system [ fhir:v "url" ] ; fhir:value [ fhir:v "http://hl7.org" ] ] [ fhir:system [ fhir:v "email" ] ; fhir:value [ fhir:v "hq@HL7.org" ] ] ) ] ) ; # fhir:description [ fhir:v "HL7-defined code system of concepts specifying the HL7 (communications) error code. Used in the ERR segment in HL7 Version 2.x messaging."] ; # fhir:purpose [ fhir:v "Underlying Master Code System for V2 table 0357 (Message Error Condition Codes)"] ; # fhir:copyright [ fhir:v "This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license"] ; # fhir:caseSensitive [ fhir:v "true"^^xsd:boolean] ; # fhir:valueSet [ fhir:v "http://terminology.hl7.org/ValueSet/v2-0357"^^xsd:anyURI ; fhir:link <http://terminology.hl7.org/ValueSet/v2-0357> ] ; # fhir:hierarchyMeaning [ fhir:v "is-a"] ; # fhir:compositional [ fhir:v "false"^^xsd:boolean] ; # fhir:versionNeeded [ fhir:v "false"^^xsd:boolean] ; # fhir:content [ fhir:v "complete"] ; # fhir:property ( [ fhir:code [ fhir:v "status" ] ; fhir:uri [ fhir:v "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status"^^xsd:anyURI ] ; fhir:description [ fhir:v "Status of the concept" ] ; fhir:type [ fhir:v "code" ] ] [ fhir:code [ fhir:v "deprecated" ] ; fhir:uri [ fhir:v "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated"^^xsd:anyURI ] ; fhir:description [ fhir:v "Version of HL7 in which the code was deprecated" ] ; fhir:type [ fhir:v "code" ] ] [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:uri [ fhir:v "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment"^^xsd:anyURI ] ; fhir:description [ fhir:v "V2 Concept Comment" ] ; fhir:type [ fhir:v "string" ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:uri [ fhir:v "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub"^^xsd:anyURI ] ; fhir:description [ fhir:v "V2 Concept Comment As Published" ] ; fhir:type [ fhir:v "string" ] ] ) ; # fhir:concept ( [ fhir:id [ fhir:v "3570" ] ; fhir:code [ fhir:v "0" ] ; fhir:display [ fhir:v "Message accepted" ] ; fhir:definition [ fhir:v "Message accepted" ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "Nachricht akzeptiert" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Success. Optional, as the AA conveys success. Used for systems that must always return a status code." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Success. Optional, as the AA conveys success. Used for systems that must always return a status code." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3571" ] ; fhir:code [ fhir:v "100" ] ; fhir:display [ fhir:v "Segment sequence error" ] ; fhir:definition [ fhir:v "Segment sequence error" ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "Fehler in der Segmentreihenfolge" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Error: The message segments were not in the proper order, or required segments are missing." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Error: The message segments were not in the proper order, or required segments are missing." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3572" ] ; fhir:code [ fhir:v "101" ] ; fhir:display [ fhir:v "Required field missing" ] ; fhir:definition [ fhir:v "Required field missing" ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "erforderliches Feld leer" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Error: A required field is missing from a segment" ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Error: A required field is missing from a segment" ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3573" ] ; fhir:code [ fhir:v "102" ] ; fhir:display [ fhir:v "Data type error" ] ; fhir:definition [ fhir:v "Data type error" ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "Datentypfehler" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Error: The field contained data of the wrong data type, e.g., an NM field contained \"FOO\"." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Error: The field contained data of the wrong data type, e.g., an NM field contained \"FOO\"." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3574" ] ; fhir:code [ fhir:v "103" ] ; fhir:display [ fhir:v "Table value not found" ] ; fhir:definition [ fhir:v "Table value not found" ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "fehlender Eintrag in der Tabelle" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Error: A field of data type ID or IS was compared against the corresponding table, and no match was found." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Error: A field of data type ID or IS was compared against the corresponding table, and no match was found." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3575" ] ; fhir:code [ fhir:v "104" ] ; fhir:display [ fhir:v "Value too long" ] ; fhir:definition [ fhir:v "Value too long" ] ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Error: a value exceeded the normative length, or the length that the application is able to safely handle." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Error: a value exceeded the normative length, or the length that the application is able to safely handle." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3576" ] ; fhir:code [ fhir:v "198" ] ; fhir:display [ fhir:v "Non-Conformant Cardinality" ] ; fhir:definition [ fhir:v "An error has been encountered related to HL7 message content. Message is not -conformant with the applicable specification’s (base standard, conformance profile or implementation profile) cardinality." ] ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Error: Cardinality is listed as [0..3] and more than 3 of the identified element are present in the message." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "N" ] ] ) ] [ fhir:id [ fhir:v "3577" ] ; fhir:code [ fhir:v "199" ] ; fhir:display [ fhir:v "Other HL7 Error" ] ; fhir:definition [ fhir:v "Any other error with the HL7 syntax that is not captured in any of the other error codes in this set." ] ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Error" ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "N" ] ] ) ] [ fhir:id [ fhir:v "3578" ] ; fhir:code [ fhir:v "200" ] ; fhir:display [ fhir:v "Unsupported message type" ] ; fhir:definition [ fhir:v "Unsupported message type" ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "Nachrichtentyp wird nicht unterstützt" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Rejection: The Message Type is not supported." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Rejection: The Message Type is not supported." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3579" ] ; fhir:code [ fhir:v "201" ] ; fhir:display [ fhir:v "Unsupported event code" ] ; fhir:definition [ fhir:v "Unsupported event code" ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "Ereignis wird nicht unterstützt" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Rejection: The Event Code is not supported." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Rejection: The Event Code is not supported." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3580" ] ; fhir:code [ fhir:v "202" ] ; fhir:display [ fhir:v "Unsupported processing id" ] ; fhir:definition [ fhir:v "Unsupported processing id" ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "Processing-ID wird nicht unterstützt" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Rejection: The Processing ID is not supported." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Rejection: The Processing ID is not supported." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3581" ] ; fhir:code [ fhir:v "203" ] ; fhir:display [ fhir:v "Unsupported version id" ] ; fhir:definition [ fhir:v "Unsupported version id" ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "Version wird nicht unterstützt" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "Rejection: The Version ID is not supported." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Rejection: The Version ID is not supported." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] [ fhir:id [ fhir:v "3582" ] ; fhir:code [ fhir:v "204" ] ; fhir:display [ fhir:v "Unknown key identifier" ] ; fhir:definition [ fhir:v "Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533." ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "Schlüsselwert nicht gefunden" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code)." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Rejection: The ID of the patient, order, etc., was not found. Used for transactions other than additions, e.g., transfer of a non-existent patient." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "B" ] ] ) ] [ fhir:id [ fhir:v "3583" ] ; fhir:code [ fhir:v "205" ] ; fhir:display [ fhir:v "Duplicate key identifier" ] ; fhir:definition [ fhir:v "Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533." ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "doppelter Schlüsselwert" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code)." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Rejection: The ID of the patient, order, etc., already exists. Used in response to addition transactions (Admit, New Order, etc.)." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "B" ] ] ) ] [ fhir:id [ fhir:v "3584" ] ; fhir:code [ fhir:v "206" ] ; fhir:display [ fhir:v "Application record locked" ] ; fhir:definition [ fhir:v "Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533." ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "Datensatz durch Applikation gesperrt" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code)." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Rejection: The transaction could not be performed at the application storage level, e.g., database locked." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "B" ] ] ) ] [ fhir:id [ fhir:v "3585" ] ; fhir:code [ fhir:v "207" ] ; fhir:display [ fhir:v "Application error" ] ; fhir:definition [ fhir:v "An application level error has occurred and the detail for that error is identified in ERR-5." ] ; ( fhir:designation [ fhir:language [ fhir:v "de" ] ; fhir:use [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra"^^xsd:anyURI ] ; fhir:code [ fhir:v "preferredForLanguage" ] ] ; fhir:value [ fhir:v "applikationsinterner Fehler" ] ] ) ; ( fhir:property [ fhir:code [ fhir:v "v2-concComment" ] ; fhir:value [ fhir:v "This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide." ] ] [ fhir:code [ fhir:v "v2-concCommentAsPub" ] ; fhir:value [ fhir:v "Rejection: A catchall for internal errors not explicitly covered by other codes." ] ] [ fhir:code [ fhir:v "status" ] ; fhir:value [ fhir:v "A" ] ] ) ] ) . #
IG © 2020+ HL7 International - Vocabulary Work Group. Package hl7.terminology#5.5.0 based on FHIR 4.0.1. Generated 2024-03-09
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change