HL7 Terminology (THO)
5.2.0 - Publication International flag

This page is part of the HL7 Terminology (v5.2.0: Release) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: orderControlCodeReason - TTL Representation

Active as of 2019-12-01

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CodeSystem ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "v2-0949"] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Properties</b></p><p><b>This code system  defines the following properties for its concepts</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>code</td><td>Status of the concept</td></tr><tr><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>code</td><td>Version of HL7 in which the code was deprecated</td></tr><tr><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>string</td><td>V2 Concept Comment</td></tr><tr><td>HL7usageNotes</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes</td><td>string</td><td>HL7 Concept Usage Notes</td></tr></table><p><b>Concepts</b></p><p>This code system <code>http://terminology.hl7.org/CodeSystem/v2-0949</code> defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Concept Comment</b></td><td><b>HL7 Concept Usage Notes</b></td></tr><tr><td style=\"white-space:nowrap\">CO<a name=\"v2-0949-CO\"> </a></td><td>Cost</td><td>Order changed based on cost</td><td>In an order replacement context, this would accompany proposal of a similar but lower cost order</td><td/></tr><tr><td style=\"white-space:nowrap\">ST<a name=\"v2-0949-ST\"> </a></td><td>Specimen Type</td><td>Incorrect specimen type submitted for the requested test</td><td>Order placer may accept, cancel and replace, or choose other testing.</td><td>Recommend testing that can use the submitted specimen type</td></tr><tr><td style=\"white-space:nowrap\">SV<a name=\"v2-0949-SV\"> </a></td><td>Specimen Volume</td><td>Provided specimen volume inadequate for testing</td><td>The question is how to use the available specimen. The Order Placer may choose a different subset of tests.</td><td>Recommend a subset of ordered tests appropriate for volume</td></tr><tr><td style=\"white-space:nowrap\">UN<a name=\"v2-0949-UN\"> </a></td><td>Unavailable test</td><td>Requested test not available</td><td>In an order replacement context, an alternative might be proposed.</td><td/></tr></table></div>"
  ] ; # 
  fhir:extension ( [
fhir:url [ fhir:v "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"^^xsd:anyURI ] ;
fhir:value [ fhir:v "oo" ]
  ] ) ; # 
  fhir:url [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0949"^^xsd:anyURI] ; # 
  fhir:identifier ( [
fhir:system [ fhir:v "urn:ietf:rfc:3986"^^xsd:anyURI ] ;
fhir:value [ fhir:v "urn:oid:2.16.840.1.113883.18.449" ]
  ] ) ; # 
  fhir:version [ fhir:v "2.1.0"] ; # 
  fhir:name [ fhir:v "OrderControlCodeReason"] ; # 
  fhir:title [ fhir:v "orderControlCodeReason"] ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:experimental [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:date [ fhir:v "2019-12-01"^^xsd:date] ; # 
  fhir:publisher [ fhir:v "HL7, Inc"] ; # 
  fhir:contact ( [
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "http://www.hl7.org/" ]     ] )
  ] ) ; # 
  fhir:description [ fhir:v "HL7-defined code system of concepts that describe reasons for the chosen order control codes. Used in HL7 Version 2 messaging in the ORC segment."] ; # 
  fhir:purpose [ fhir:v "Underlying Master Code System for V2 table 0949 (Order Control Code Reason)"] ; # 
  fhir:copyright [ fhir:v "Copyright HL7. Licensed under creative commons public domain"] ; # 
  fhir:caseSensitive [ fhir:v "true"^^xsd:boolean] ; # 
  fhir:valueSet [
fhir:v "http://terminology.hl7.org/ValueSet/v2-0949"^^xsd:anyURI ;
fhir:link <http://terminology.hl7.org/ValueSet/v2-0949>
  ] ; # 
  fhir:hierarchyMeaning [ fhir:v "is-a"] ; # 
  fhir:compositional [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:versionNeeded [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:content [ fhir:v "complete"] ; # 
  fhir:property ( [
fhir:code [ fhir:v "status" ] ;
fhir:uri [ fhir:v "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status"^^xsd:anyURI ] ;
fhir:description [ fhir:v "Status of the concept" ] ;
fhir:type [ fhir:v "code" ]
  ] [
fhir:code [ fhir:v "deprecated" ] ;
fhir:uri [ fhir:v "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated"^^xsd:anyURI ] ;
fhir:description [ fhir:v "Version of HL7 in which the code was deprecated" ] ;
fhir:type [ fhir:v "code" ]
  ] [
fhir:code [ fhir:v "v2-concComment" ] ;
fhir:uri [ fhir:v "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment"^^xsd:anyURI ] ;
fhir:description [ fhir:v "V2 Concept Comment" ] ;
fhir:type [ fhir:v "string" ]
  ] [
fhir:code [ fhir:v "HL7usageNotes" ] ;
fhir:uri [ fhir:v "http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes"^^xsd:anyURI ] ;
fhir:description [ fhir:v "HL7 Concept Usage Notes" ] ;
fhir:type [ fhir:v "string" ]
  ] ) ; # 
  fhir:concept ( [
fhir:id [ fhir:v "6769" ] ;
fhir:code [ fhir:v "CO" ] ;
fhir:display [ fhir:v "Cost" ] ;
fhir:definition [ fhir:v "Order changed based on cost" ] ;
    ( fhir:property [
fhir:code [ fhir:v "v2-concComment" ] ;
fhir:value [ fhir:v "In an order replacement context, this would accompany proposal of a similar but lower cost order" ]     ] [
fhir:code [ fhir:v "status" ] ;
fhir:value [ fhir:v "N" ]     ] )
  ] [
fhir:id [ fhir:v "6770" ] ;
fhir:code [ fhir:v "ST" ] ;
fhir:display [ fhir:v "Specimen Type" ] ;
fhir:definition [ fhir:v "Incorrect specimen type submitted for the requested test" ] ;
    ( fhir:property [
fhir:code [ fhir:v "v2-concComment" ] ;
fhir:value [ fhir:v "Order placer may accept, cancel and replace, or choose other testing." ]     ] [
fhir:code [ fhir:v "HL7usageNotes" ] ;
fhir:value [ fhir:v "Recommend testing that can use the submitted specimen type" ]     ] [
fhir:code [ fhir:v "status" ] ;
fhir:value [ fhir:v "N" ]     ] )
  ] [
fhir:id [ fhir:v "6771" ] ;
fhir:code [ fhir:v "SV" ] ;
fhir:display [ fhir:v "Specimen Volume" ] ;
fhir:definition [ fhir:v "Provided specimen volume inadequate for testing" ] ;
    ( fhir:property [
fhir:code [ fhir:v "v2-concComment" ] ;
fhir:value [ fhir:v "The question is how to use the available specimen. The Order Placer may choose a different subset of tests." ]     ] [
fhir:code [ fhir:v "HL7usageNotes" ] ;
fhir:value [ fhir:v "Recommend a subset of ordered tests appropriate for volume" ]     ] [
fhir:code [ fhir:v "status" ] ;
fhir:value [ fhir:v "N" ]     ] )
  ] [
fhir:id [ fhir:v "6772" ] ;
fhir:code [ fhir:v "UN" ] ;
fhir:display [ fhir:v "Unavailable test" ] ;
fhir:definition [ fhir:v "Requested test not available" ] ;
    ( fhir:property [
fhir:code [ fhir:v "v2-concComment" ] ;
fhir:value [ fhir:v "In an order replacement context, an alternative might be proposed." ]     ] [
fhir:code [ fhir:v "status" ] ;
fhir:value [ fhir:v "N" ]     ] )
  ] ) . #