Code | Display | status | deprecated | v2-concComment | v2-concCommentAsPub | Comments |
---|
FLS | Flash | A | A | | Used to quickly sterilize instruments that were dropped during surgery. | Used to quickly sterilize instruments that were dropped during surgery. | Used to quickly sterilize instruments that were dropped during surgery. | Used to quickly sterilize instruments that were dropped during surgery. | |
PRV | Prevac | A | A | | A prevac cycle is vacuum assisted. | A prevac cycle is vacuum assisted. | A prevac cycle is vacuum assisted. | A prevac cycle is vacuum assisted. | |
GRV | Gravity | A | A | | A gravity cycle is executed at atmospheric pressure. | A gravity cycle is executed at atmospheric pressure. | A gravity cycle is executed at atmospheric pressure. | A gravity cycle is executed at atmospheric pressure. | |
LQD | Liquid | A | A | | A cycle specific to sterilizing liquids. | A cycle specific to sterilizing liquids. | A cycle specific to sterilizing liquids. | A cycle specific to sterilizing liquids. | |
EXP | Express | A | A | | An express cycle is similar to a flash cycle but the supply item is wrapped. | An express cycle is similar to a flash cycle but the supply item is wrapped. | An express cycle is similar to a flash cycle but the supply item is wrapped. | An express cycle is similar to a flash cycle but the supply item is wrapped. | |
DRT | Dart | A | A | | A dart cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum. | A dart cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum. | A dart cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum. | A dart cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum. | |
DRW | Dart Warm-up Cycle | A | A | | A dart warm-up cycle is used to bring the sterilizer chamber up to operating temperature in order to run a dart test cycle. | A dart warm-up cycle is used to bring the sterilizer chamber up to operating temperature in order to run a dart test cycle. | A dart warm-up cycle is used to bring the sterilizer chamber up to operating temperature in order to run a dart test cycle. | A dart warm-up cycle is used to bring the sterilizer chamber up to operating temperature in order to run a dart test cycle. | |
THR | Thermal | A | A | | | | |
ISO | Isothermal | A | A | | | | |
BWD | Bowie-Dick Test | A | A | | A Bowie-Dick test cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum. | A Bowie-Dick test cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum. | A Bowie-Dick test cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum. | A Bowie-Dick test cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum. | |
LKT | Leak Test | A | A | | A leak test cycle tests the integrity of the sterilizer chamber to hold a vacuum over a specific period of time. | A leak test cycle tests the integrity of the sterilizer chamber to hold a vacuum over a specific period of time. | A leak test cycle tests the integrity of the sterilizer chamber to hold a vacuum over a specific period of time. | A leak test cycle tests the integrity of the sterilizer chamber to hold a vacuum over a specific period of time. | |
WFP | Wrap/Steam Flush Pressure Pulse (Wrap/SFPP) | A | A | | A Wrap/SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is unwrapped. | A Wrap/SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is unwrapped. | A Wrap/SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is unwrapped. | A Wrap/SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is unwrapped. | |
SFP | Steam Flush Pressure Pulse | A | A | | An SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is wrapped. | An SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is wrapped. | An SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is wrapped. | An SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is wrapped. | |
CMW | Chemical Wash | A | A | | A chemical wash cycle. | A chemical wash cycle. | A chemical wash cycle. | A chemical wash cycle. | |
PEA | Peracetic Acid | A | A | | A peracetic acid cycle. | A peracetic acid cycle. | A peracetic acid cycle. | A peracetic acid cycle. | |
EOH | EO High Temperature | A | A | | | | |
EOL | EO Low Temperature | A | A | | | | |
CRT | Cart Wash | A | A | | | | |
UTL | Utensil Wash | A | A | | | | |
IST | Instrument Wash | A | A | | | | |
GLS | Glassware | A | A | | | | |
PLA | Plastic Goods Wash | A | A | | | | |
ANR | Anesthesia/Respiratory | A | A | | Special Wash cycle | Special Wash cycle | Special Wash cycle | Special Wash cycle | |
GTL | Gentle | A | A | | | | |
OPW | Optional Wash | A | A | | Any Optional Wash cycle | Any Optional Wash cycle | Any Optional Wash cycle | Any Optional Wash cycle | |
BDP | Bedpans | A | A | | | | |
TRB | Tray/Basin | A | A | | | | |
GNP | Gen. Purpose | A | A | | | | |
COD | Code | A | A | | | | |
RNS | Rinse | A | A | | | | |
2RS | Second Rinse | A | A | | | | |
DEC | Decontamination | A | A | | | | |