This page is part of the HL7 Terminology (v5.1.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions
Active as of 2019-03-20 |
<CodeSystem xmlns="http://hl7.org/fhir">
<id value="v3-hl7V3Conformance"/>
<language value="en"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml" xml:lang="en" lang="en"><p><b>Properties</b></p><p><b>This code system defines the following properties for its concepts</b></p><table class="grid"><tr><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>Specializes</td><td/><td>Coding</td><td>The child code is a more narrow version of the concept represented by the parent code. I.e. Every child concept is also a valid parent concept. Used to allow determination of subsumption. Must be transitive, irreflexive, antisymmetric.</td></tr><tr><td>Generalizes</td><td/><td>Coding</td><td>Inverse of Specializes. Only included as a derived relationship.</td></tr><tr><td>internalId</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v3-internal-id</td><td>code</td><td>The internal identifier for the concept in the HL7 Access database repository.</td></tr><tr><td>status</td><td>http://hl7.org/fhir/concept-properties#status</td><td>code</td><td>Designation of a concept's state. Normally is not populated unless the state is retired.</td></tr></table><p><b>Concepts</b></p><p>This code system <code>http://terminology.hl7.org/CodeSystem/v3-hl7V3Conformance</code> defines the following codes:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>internalId</b></td><td><b>status</b></td></tr><tr><td style="white-space:nowrap">I<a name="v3-hl7V3Conformance-I"> </a></td><td>ignored</td><td>**Description:** Implementers receiving this property must not raise an error if the data is received, but will not perform any useful function with the data. This conformance level is not used in profiles or other artifacts that are specific to the "sender" or "initiator" of a communication.</td><td>23001</td><td>active</td></tr><tr><td style="white-space:nowrap">NP<a name="v3-hl7V3Conformance-NP"> </a></td><td>not permitted</td><td>**Description:** All implementers are prohibited from transmitting this content, and may raise an error if they receive it.</td><td>23000</td><td>active</td></tr><tr><td style="white-space:nowrap">R<a name="v3-hl7V3Conformance-R"> </a></td><td>required</td><td>**Description:** All implementers must support this property. I.e. they must be able to transmit, or to receive and usefully handle the concept.</td><td>22999</td><td>active</td></tr><tr><td style="white-space:nowrap">RC<a name="v3-hl7V3Conformance-RC"> </a></td><td>required for consumer</td><td>**Description:** The element is considered "required" (i.e. must be supported) from the perspective of systems that consume instances, but is "undetermined" for systems that generate instances. Used only as part of specifications that define both initiator and consumer expectations.</td><td>23003</td><td>active</td></tr><tr><td style="white-space:nowrap">RI<a name="v3-hl7V3Conformance-RI"> </a></td><td>required for initiator</td><td>**Description:** The element is considered "required" (i.e. must be supported) from the perspective of systems that generate instances, but is "undetermined" for systems that consume instances. Used only as part of specifications that define both initiator and consumer expectations.</td><td>23002</td><td>active</td></tr><tr><td style="white-space:nowrap">U<a name="v3-hl7V3Conformance-U"> </a></td><td>undetermined</td><td>**Description:** The conformance expectations for this element have not yet been determined.</td><td>22998</td><td>active</td></tr></table></div>
</text>
<url value="http://terminology.hl7.org/CodeSystem/v3-hl7V3Conformance"/>
<identifier>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.5.1125"/>
</identifier>
<version value="2.1.0"/>
<name value="Hl7V3Conformance"/>
<title value="HL7V3Conformance"/>
<status value="active"/>
<experimental value="false"/>
<date value="2019-03-20"/>
<publisher value="HL7"/>
<contact>
<name value="Health Level Seven"/>
</contact>
<description
value="**Description:** Identifies allowed codes for HL7aTMs v3 conformance property."/>
<caseSensitive value="true"/>
<hierarchyMeaning value="is-a"/>
<content value="complete"/>
<property>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-symmetry">
<valueCode value="antisymmetric"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-transitivity">
<valueCode value="transitive"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-reflexivity">
<valueCode value="irreflexive"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-isNavigable">
<valueBoolean value="true"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-relationshipKind">
<valueCode value="Specializes"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-inverseName">
<valueString value="Generalizes"/>
</extension>
<code value="Specializes"/>
<description
value="The child code is a more narrow version of the concept represented by the parent code. I.e. Every child concept is also a valid parent concept. Used to allow determination of subsumption. Must be transitive, irreflexive, antisymmetric."/>
<type value="Coding"/>
</property>
<property>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-symmetry">
<valueCode value="antisymmetric"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-transitivity">
<valueCode value="transitive"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-reflexivity">
<valueCode value="irreflexive"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-isNavigable">
<valueBoolean value="true"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-relationshipKind">
<valueCode value="Generalizes"/>
</extension>
<extension
url="http://terminology.hl7.org/StructureDefinition/ext-mif-relationship-inverseName">
<valueString value="Specializes"/>
</extension>
<code value="Generalizes"/>
<description
value="Inverse of Specializes. Only included as a derived relationship."/>
<type value="Coding"/>
</property>
<property>
<code value="internalId"/>
<uri
value="http://terminology.hl7.org/CodeSystem/utg-concept-properties#v3-internal-id"/>
<description
value="The internal identifier for the concept in the HL7 Access database repository."/>
<type value="code"/>
</property>
<property>
<code value="status"/>
<uri value="http://hl7.org/fhir/concept-properties#status"/>
<description
value="Designation of a concept's state. Normally is not populated unless the state is retired."/>
<type value="code"/>
</property>
<concept>
<code value="I"/>
<display value="ignored"/>
<definition
value="**Description:** Implementers receiving this property must not raise an error if the data is received, but will not perform any useful function with the data. This conformance level is not used in profiles or other artifacts that are specific to the "sender" or "initiator" of a communication."/>
<property>
<code value="status"/>
<valueCode value="active"/>
</property>
<property>
<code value="internalId"/>
<valueCode value="23001"/>
</property>
</concept>
<concept>
<code value="NP"/>
<display value="not permitted"/>
<definition
value="**Description:** All implementers are prohibited from transmitting this content, and may raise an error if they receive it."/>
<property>
<code value="status"/>
<valueCode value="active"/>
</property>
<property>
<code value="internalId"/>
<valueCode value="23000"/>
</property>
</concept>
<concept>
<code value="R"/>
<display value="required"/>
<definition
value="**Description:** All implementers must support this property. I.e. they must be able to transmit, or to receive and usefully handle the concept."/>
<property>
<code value="status"/>
<valueCode value="active"/>
</property>
<property>
<code value="internalId"/>
<valueCode value="22999"/>
</property>
</concept>
<concept>
<code value="RC"/>
<display value="required for consumer"/>
<definition
value="**Description:** The element is considered "required" (i.e. must be supported) from the perspective of systems that consume instances, but is "undetermined" for systems that generate instances. Used only as part of specifications that define both initiator and consumer expectations."/>
<property>
<code value="status"/>
<valueCode value="active"/>
</property>
<property>
<code value="internalId"/>
<valueCode value="23003"/>
</property>
</concept>
<concept>
<code value="RI"/>
<display value="required for initiator"/>
<definition
value="**Description:** The element is considered "required" (i.e. must be supported) from the perspective of systems that generate instances, but is "undetermined" for systems that consume instances. Used only as part of specifications that define both initiator and consumer expectations."/>
<property>
<code value="status"/>
<valueCode value="active"/>
</property>
<property>
<code value="internalId"/>
<valueCode value="23002"/>
</property>
</concept>
<concept>
<code value="U"/>
<display value="undetermined"/>
<definition
value="**Description:** The conformance expectations for this element have not yet been determined."/>
<property>
<code value="status"/>
<valueCode value="active"/>
</property>
<property>
<code value="internalId"/>
<valueCode value="22998"/>
</property>
</concept>
</CodeSystem>
IG © 2020+ HL7 International - Vocabulary Work Group. Package hl7.terminology#5.1.0 based on FHIR 4.0.1. Generated 2023-02-25
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change