HL7 Terminology (THO)
5.1.0 - Publication International flag

This page is part of the HL7 Terminology (v5.1.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions

: universalIdType - TTL Representation

Active as of 2019-12-01

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CodeSystem;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "v2-0301"]; # 
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Properties</b></p><p><b>This code system  defines the following properties for its concepts</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>code</td><td>Status of the concept</td></tr><tr><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>code</td><td>Version of HL7 in which the code was deprecated</td></tr><tr><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>string</td><td>V2 Concept Comment</td></tr><tr><td>v2-concCommentAsPub</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub</td><td>string</td><td>V2 Concept Comment As Published</td></tr><tr><td>HL7usageNotes</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes</td><td>string</td><td>HL7 Concept Usage Notes</td></tr></table><p><b>Concepts</b></p><p>This code system <code>http://terminology.hl7.org/CodeSystem/v2-0301</code> defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Concept Comment</b></td><td><b>V2 Concept Comment As Published</b></td><td><b>HL7 Concept Usage Notes</b></td></tr><tr><td style=\"white-space:nowrap\">CAP<a name=\"v2-0301-CAP\"> </a></td><td>College of American Pathologist Accreditation Number</td><td>Allows for the ability to designate organization identifier as a &quot;CAP&quot; assigned number (for labs)</td><td>Use to identify assigning authority IDs, when an OID is not available.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">CLIA<a name=\"v2-0301-CLIA\"> </a></td><td>Clinical Laboratory Improvement Amendments</td><td>Clinical Laboratory Improvement Amendments. Allows for the ability to designate organization identifier as a &quot;CLIA&quot; assigned number (for labs)</td><td>Allows for the ability to designate organization identifier as a “CLIA” assigned number (for labs)</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">CLIP<a name=\"v2-0301-CLIP\"> </a></td><td>Clinical laboratory Improvement Program</td><td>Clinical laboratory Improvement Program. Allows for the ability to designate organization identifier as a &quot;CLIP&quot; assigned number (for labs).  Used by US Department of Defense.</td><td>Allows for the ability to designate organization identifier as a “CLIP” assigned number (for labs).  Used by US Department of Defense.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">DNS<a name=\"v2-0301-DNS\"> </a></td><td>Domain Name System</td><td>An Internet host name, in accordance with RFC 1035; or an IP address. Either in ASCII or as integers, with periods between components (&quot;dotted&quot; notation).</td><td>An Internet host name, in accordance with RFC 1035; or an IP address. Either in ASCII or as integers, with periods between components (“dotted” notation).</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">EUI64<a name=\"v2-0301-EUI64\"> </a></td><td>IEEE 64-bit Extended Unique Identifier</td><td>IEEE 64-bit Extended Unique Identifier is comprised of a  24-bit company identifier and a 40-bit instance identifier.  The value shall be formatted as 16 ASCII HEX digits, for example, “AABBCC1122334455”.  The 24-bit company identifier, formally known as Organizationally Unique Identifier (OUI-24), is guaranteed to be globally unique.  The 40-bit extensions are assigned by manufacturers.  This identifier is often used in equipment interfaces (e.g., “MAC” address format for IPv4 &amp; IPv6).  [See http://standards.ieee.org/regauth/oui/tutorials/EUI64.html for a detailed explanation of the format.]</td><td>IEEE 64-bit Extended Unique Identifier is comprised of a  24-bit company identifier and a 40-bit instance identifier.  The value shall be formatted as 16 ASCII HEX digits, for example, “AABBCC1122334455”.  The 24-bit company identifier, formally known as Organizationally Unique Identifier (OUI-24), is guaranteed to be globally unique.  The 40-bit extensions are assigned by manufacturers.  This identifier is often used in equipment interfaces (e.g., “MAC” address format for IPv4 &amp; IPv6).  [See http://standards.ieee.org/regauth/oui/tutorials/EUI64.htmlfor a detailed explanation of the format.]OUI-24 values are administered by the IEEE Registration Authority.</td><td>OUI-24 values are administered by the IEEE Registration Authority.</td><td/></tr><tr><td style=\"white-space:nowrap\">GUID<a name=\"v2-0301-GUID\"> </a></td><td>globally unique identifier</td><td>Same as UUID.</td><td>Same as UUID. Retained for backward compatibility only as of v2.7; use UUID instead</td><td>Retained for backward compatibility only as of v2.7; use UUID instead</td><td/></tr><tr><td style=\"white-space:nowrap\">HCD<a name=\"v2-0301-HCD\"> </a></td><td>CEN Healthcare Coding Identifier</td><td>The CEN Healthcare Coding Scheme Designator</td><td>The CEN Healthcare Coding Scheme Designator. Retained for backward compatibility only as of v2.7; does not identify Assigning Authorities</td><td>Retained for backward compatibility only as of v2.7; does not identify Assigning Authorities</td><td/></tr><tr><td style=\"white-space:nowrap\">HL7<a name=\"v2-0301-HL7\"> </a></td><td>HL7 registration schemes</td><td>HL7 registration schemes</td><td>Retained for backward compatibility only as of v2.7; HL7 assigns ISO OIDs for Assigning Authorities</td><td>Retained for backward compatibility only as of v2.7; HL7 assigns ISO OIDs for Assigning Authorities</td><td/></tr><tr><td style=\"white-space:nowrap\">ISO<a name=\"v2-0301-ISO\"> </a></td><td>ISO Object Identifier</td><td>An International Standards Organization Object Identifier (OID), in accordance with ISO/IEC 8824.  Formatted as decimal digits separated by periods; recommended limit of 64 characters</td><td>An International Standards Organization Object Identifier (OID), in accordance with ISO/IEC 8824.  Formatted as decimal digits separated by periods; recommended limit of 64 characters</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">L<a name=\"v2-0301-L\"> </a></td><td>Local</td><td>These are reserved for locally defined coding schemes.</td><td>Locally defined coding entity identifier.Retained for backward compatibility only as of v 2.8</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">L,M,N<a name=\"v2-0301-L.44M.44N\"> </a></td><td>Local</td><td>These are reserved for locally defined coding schemes.</td><td>Locally defined coding entity identifier.Retained for backward compatibility only as of v 2.8</td><td>Retained for backward compatibility only as of v 2.8</td><td/></tr><tr><td style=\"white-space:nowrap\">M<a name=\"v2-0301-M\"> </a></td><td>Local</td><td>These are reserved for locally defined coding schemes.</td><td>Locally defined coding entity identifier.Retained for backward compatibility only as of v 2.8</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">N<a name=\"v2-0301-N\"> </a></td><td>Local</td><td>These are reserved for locally defined coding schemes.</td><td>Locally defined coding entity identifier.Retained for backward compatibility only as of v 2.8</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">NPI<a name=\"v2-0301-NPI\"> </a></td><td>US National Provider Identifier</td><td>Allows for the ability to designate organization identifier as a &quot;NPI&quot; assigned number (lab, any medical provider, can be a person or an organization)</td><td>Use to identify assigning authority IDs, when an OID is not available.  Especially important in the CNN datatype. Namespace maintained and published in the US.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">Random<a name=\"v2-0301-Random\"> </a></td><td>Random</td><td>Usually a base64 encoded string of random bits.&lt;p&gt;Note: Random IDs are typically used for instance identifiers, rather than an identifier of an Assigning Authority that issues instance identifiers</td><td>Usually a base64 encoded string of random bits.Retained for backward compatibility only as of v2.7; equivalent to a locally defined entity identifier scheme; use L. M, or N instead. Note: Random IDs are typically used for instance identifiers, rather than an identifier of an Assigning Authority that issues instance identifiers</td><td>Retained for backward compatibility only as of v2.7; equivalent to a locally defined entity identifier scheme; use L. M, or N instead.</td><td>Retained for backward compatibility only as of v2.7; equivalent to a locally defined entity identifier scheme; use L. M, or N instead.</td></tr><tr><td style=\"white-space:nowrap\">URI<a name=\"v2-0301-URI\"> </a></td><td>Uniform Resource Identifier</td><td>Uniform Resource Identifier</td><td/><td/><td/></tr><tr><td style=\"white-space:nowrap\">UUID<a name=\"v2-0301-UUID\"> </a></td><td>Universal Unique Identifier</td><td>The DCE Universal Unique Identifier, in accordance with RFC 4122. Recommended format is 32 hexadecimal digits separated by hyphens, in the digit grouping 8-4-4-4-12</td><td>The DCE Universal Unique Identifier, in accordance with RFC 4122. Recommended format is 32 hexadecimal digits separated by hyphens, in the digit grouping 8-4-4-4-12</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">x400<a name=\"v2-0301-x400\"> </a></td><td>X.400 MHS identifier</td><td>An X.400 MHS identifier. Recommended format is in accordance with RFC 1649</td><td>Recommended format is in accordance with RFC 1649</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">x500<a name=\"v2-0301-x500\"> </a></td><td>X500 directory Name</td><td>An X.500 directory name</td><td/><td/><td/></tr></table><p><b>Additional Language Displays</b></p><table class=\"codes\"><tr><td><b>Code</b></td><td><b>Deutsch (German, de)</b></td></tr><tr><td>CAP</td><td></td></tr><tr><td>CLIA</td><td></td></tr><tr><td>CLIP</td><td></td></tr><tr><td>DNS</td><td>Internet-Adresse</td></tr><tr><td>EUI64</td><td></td></tr><tr><td>GUID</td><td>GUID</td></tr><tr><td>HCD</td><td></td></tr><tr><td>HL7</td><td>für HL7 reserviert</td></tr><tr><td>ISO</td><td>ISO-ID</td></tr><tr><td>L</td><td>reserviert für lokale Tabellen</td></tr><tr><td>L,M,N</td><td>reserviert für lokale Tabellen</td></tr><tr><td>M</td><td>reserviert für lokale Tabellen</td></tr><tr><td>N</td><td>reserviert für lokale Tabellen</td></tr><tr><td>NPI</td><td></td></tr><tr><td>Random</td><td>beliebig</td></tr><tr><td>URI</td><td>URI</td></tr><tr><td>UUID</td><td>UUID</td></tr><tr><td>x400</td><td>X.400</td></tr><tr><td>x500</td><td>X.500 Verzeichnis­name</td></tr></table></div>"
  ]; # 
  fhir:DomainResource.extension [
     fhir:index 0;
     fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg" ];
     fhir:Extension.valueCode [ fhir:value "inm" ]
  ]; # 
  fhir:CodeSystem.url [ fhir:value "http://terminology.hl7.org/CodeSystem/v2-0301"]; # 
  fhir:CodeSystem.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "urn:ietf:rfc:3986" ];
     fhir:Identifier.value [ fhir:value "urn:oid:2.16.840.1.113883.18.186" ]
  ]; # 
  fhir:CodeSystem.version [ fhir:value "2.2.0"]; # 
  fhir:CodeSystem.name [ fhir:value "UniversalIdType"]; # 
  fhir:CodeSystem.title [ fhir:value "universalIdType"]; # 
  fhir:CodeSystem.status [ fhir:value "active"]; # 
  fhir:CodeSystem.experimental [ fhir:value "false"^^xsd:boolean]; # 
  fhir:CodeSystem.date [ fhir:value "2019-12-01"^^xsd:date]; # 
  fhir:CodeSystem.publisher [ fhir:value "HL7, Inc"]; # 
  fhir:CodeSystem.contact [
     fhir:index 0;
     fhir:ContactDetail.telecom [
       fhir:index 0;
       fhir:ContactPoint.system [ fhir:value "url" ];
       fhir:ContactPoint.value [ fhir:value "http://www.hl7.org/" ]     ]
  ]; # 
  fhir:CodeSystem.description [ fhir:value "HL7-defined code system of types of UID (Universal Identifiers).   Used in HL7 Version 2.x messaging HD and EI datatypes."]; # 
  fhir:CodeSystem.purpose [ fhir:value "Underlying Master Code System for V2 table 0301 (Universal ID Type)"]; # 
  fhir:CodeSystem.copyright [ fhir:value "Copyright HL7. Licensed under creative commons public domain"]; # 
  fhir:CodeSystem.caseSensitive [ fhir:value "true"^^xsd:boolean]; # 
  fhir:CodeSystem.valueSet [
     fhir:value "http://terminology.hl7.org/ValueSet/v2-0301";
     fhir:link <http://terminology.hl7.org/ValueSet/v2-0301>
  ]; # 
  fhir:CodeSystem.hierarchyMeaning [ fhir:value "is-a"]; # 
  fhir:CodeSystem.compositional [ fhir:value "false"^^xsd:boolean]; # 
  fhir:CodeSystem.versionNeeded [ fhir:value "false"^^xsd:boolean]; # 
  fhir:CodeSystem.content [ fhir:value "complete"]; # 
  fhir:CodeSystem.property [
     fhir:index 0;
     fhir:CodeSystem.property.code [ fhir:value "status" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status" ];
     fhir:CodeSystem.property.description [ fhir:value "Status of the concept" ];
     fhir:CodeSystem.property.type [ fhir:value "code" ]
  ], [
     fhir:index 1;
     fhir:CodeSystem.property.code [ fhir:value "deprecated" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated" ];
     fhir:CodeSystem.property.description [ fhir:value "Version of HL7 in which the code was deprecated" ];
     fhir:CodeSystem.property.type [ fhir:value "code" ]
  ], [
     fhir:index 2;
     fhir:CodeSystem.property.code [ fhir:value "v2-concComment" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment" ];
     fhir:CodeSystem.property.description [ fhir:value "V2 Concept Comment" ];
     fhir:CodeSystem.property.type [ fhir:value "string" ]
  ], [
     fhir:index 3;
     fhir:CodeSystem.property.code [ fhir:value "v2-concCommentAsPub" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub" ];
     fhir:CodeSystem.property.description [ fhir:value "V2 Concept Comment As Published" ];
     fhir:CodeSystem.property.type [ fhir:value "string" ]
  ], [
     fhir:index 4;
     fhir:CodeSystem.property.code [ fhir:value "HL7usageNotes" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes" ];
     fhir:CodeSystem.property.description [ fhir:value "HL7 Concept Usage Notes" ];
     fhir:CodeSystem.property.type [ fhir:value "string" ]
  ]; # 
  fhir:CodeSystem.concept [
     fhir:index 0;
     fhir:Element.id [ fhir:value "2977" ];
     fhir:CodeSystem.concept.code [ fhir:value "CAP" ];
     fhir:CodeSystem.concept.display [ fhir:value "College of American Pathologist Accreditation Number" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Allows for the ability to designate organization identifier as a \"CAP\" assigned number (for labs)" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Use to identify assigning authority IDs, when an OID is not available." ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 1;
     fhir:Element.id [ fhir:value "2978" ];
     fhir:CodeSystem.concept.code [ fhir:value "CLIA" ];
     fhir:CodeSystem.concept.display [ fhir:value "Clinical Laboratory Improvement Amendments" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Clinical Laboratory Improvement Amendments. Allows for the ability to designate organization identifier as a \"CLIA\" assigned number (for labs)" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Allows for the ability to designate organization identifier as a “CLIA” assigned number (for labs)" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 2;
     fhir:Element.id [ fhir:value "2979" ];
     fhir:CodeSystem.concept.code [ fhir:value "CLIP" ];
     fhir:CodeSystem.concept.display [ fhir:value "Clinical laboratory Improvement Program" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Clinical laboratory Improvement Program. Allows for the ability to designate organization identifier as a \"CLIP\" assigned number (for labs).  Used by US Department of Defense." ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Allows for the ability to designate organization identifier as a “CLIP” assigned number (for labs).  Used by US Department of Defense." ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 3;
     fhir:Element.id [ fhir:value "2980" ];
     fhir:CodeSystem.concept.code [ fhir:value "DNS" ];
     fhir:CodeSystem.concept.display [ fhir:value "Domain Name System" ];
     fhir:CodeSystem.concept.definition [ fhir:value "An Internet host name, in accordance with RFC 1035; or an IP address. Either in ASCII or as integers, with periods between components (\"dotted\" notation)." ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "Internet-Adresse" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "An Internet host name, in accordance with RFC 1035; or an IP address. Either in ASCII or as integers, with periods between components (“dotted” notation)." ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 4;
     fhir:Element.id [ fhir:value "2981" ];
     fhir:CodeSystem.concept.code [ fhir:value "EUI64" ];
     fhir:CodeSystem.concept.display [ fhir:value "IEEE 64-bit Extended Unique Identifier" ];
     fhir:CodeSystem.concept.definition [ fhir:value "IEEE 64-bit Extended Unique Identifier is comprised of a  24-bit company identifier and a 40-bit instance identifier.  The value shall be formatted as 16 ASCII HEX digits, for example, “AABBCC1122334455”.  The 24-bit company identifier, formally known as Organizationally Unique Identifier (OUI-24), is guaranteed to be globally unique.  The 40-bit extensions are assigned by manufacturers.  This identifier is often used in equipment interfaces (e.g., “MAC” address format for IPv4 & IPv6).  [See http://standards.ieee.org/regauth/oui/tutorials/EUI64.html for a detailed explanation of the format.]" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "IEEE 64-bit Extended Unique Identifier is comprised of a  24-bit company identifier and a 40-bit instance identifier.  The value shall be formatted as 16 ASCII HEX digits, for example, “AABBCC1122334455”.  The 24-bit company identifier, formally known as Organizationally Unique Identifier (OUI-24), is guaranteed to be globally unique.  The 40-bit extensions are assigned by manufacturers.  This identifier is often used in equipment interfaces (e.g., “MAC” address format for IPv4 & IPv6).  [See http://standards.ieee.org/regauth/oui/tutorials/EUI64.htmlfor a detailed explanation of the format.]OUI-24 values are administered by the IEEE Registration Authority." ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concCommentAsPub" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "OUI-24 values are administered by the IEEE Registration Authority." ]     ], [
       fhir:index 2;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 5;
     fhir:Element.id [ fhir:value "2982" ];
     fhir:CodeSystem.concept.code [ fhir:value "GUID" ];
     fhir:CodeSystem.concept.display [ fhir:value "globally unique identifier" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Same as UUID." ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "GUID" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Same as UUID. Retained for backward compatibility only as of v2.7; use UUID instead" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concCommentAsPub" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Retained for backward compatibility only as of v2.7; use UUID instead" ]     ], [
       fhir:index 2;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 6;
     fhir:Element.id [ fhir:value "2983" ];
     fhir:CodeSystem.concept.code [ fhir:value "HCD" ];
     fhir:CodeSystem.concept.display [ fhir:value "CEN Healthcare Coding Identifier" ];
     fhir:CodeSystem.concept.definition [ fhir:value "The CEN Healthcare Coding Scheme Designator" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "The CEN Healthcare Coding Scheme Designator. Retained for backward compatibility only as of v2.7; does not identify Assigning Authorities" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concCommentAsPub" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Retained for backward compatibility only as of v2.7; does not identify Assigning Authorities" ]     ], [
       fhir:index 2;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 7;
     fhir:Element.id [ fhir:value "2984" ];
     fhir:CodeSystem.concept.code [ fhir:value "HL7" ];
     fhir:CodeSystem.concept.display [ fhir:value "HL7 registration schemes" ];
     fhir:CodeSystem.concept.definition [ fhir:value "HL7 registration schemes" ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "für HL7 reserviert" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Retained for backward compatibility only as of v2.7; HL7 assigns ISO OIDs for Assigning Authorities" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concCommentAsPub" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Retained for backward compatibility only as of v2.7; HL7 assigns ISO OIDs for Assigning Authorities" ]     ], [
       fhir:index 2;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 8;
     fhir:Element.id [ fhir:value "2985" ];
     fhir:CodeSystem.concept.code [ fhir:value "ISO" ];
     fhir:CodeSystem.concept.display [ fhir:value "ISO Object Identifier" ];
     fhir:CodeSystem.concept.definition [ fhir:value "An International Standards Organization Object Identifier (OID), in accordance with ISO/IEC 8824.  Formatted as decimal digits separated by periods; recommended limit of 64 characters" ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "ISO-ID" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "An International Standards Organization Object Identifier (OID), in accordance with ISO/IEC 8824.  Formatted as decimal digits separated by periods; recommended limit of 64 characters" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 9;
     fhir:Element.id [ fhir:value "2986" ];
     fhir:CodeSystem.concept.code [ fhir:value "L" ];
     fhir:CodeSystem.concept.display [ fhir:value "Local" ];
     fhir:CodeSystem.concept.definition [ fhir:value "These are reserved for locally defined coding schemes." ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "reserviert für lokale Tabellen" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Locally defined coding entity identifier.Retained for backward compatibility only as of v 2.8" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 10;
     fhir:Element.id [ fhir:value "2987" ];
     fhir:CodeSystem.concept.code [ fhir:value "L,M,N" ];
     fhir:CodeSystem.concept.display [ fhir:value "Local" ];
     fhir:CodeSystem.concept.definition [ fhir:value "These are reserved for locally defined coding schemes." ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "reserviert für lokale Tabellen" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Locally defined coding entity identifier.Retained for backward compatibility only as of v 2.8" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concCommentAsPub" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Retained for backward compatibility only as of v 2.8" ]     ], [
       fhir:index 2;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "D" ]     ]
  ], [
     fhir:index 11;
     fhir:Element.id [ fhir:value "2988" ];
     fhir:CodeSystem.concept.code [ fhir:value "M" ];
     fhir:CodeSystem.concept.display [ fhir:value "Local" ];
     fhir:CodeSystem.concept.definition [ fhir:value "These are reserved for locally defined coding schemes." ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "reserviert für lokale Tabellen" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Locally defined coding entity identifier.Retained for backward compatibility only as of v 2.8" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 12;
     fhir:Element.id [ fhir:value "2989" ];
     fhir:CodeSystem.concept.code [ fhir:value "N" ];
     fhir:CodeSystem.concept.display [ fhir:value "Local" ];
     fhir:CodeSystem.concept.definition [ fhir:value "These are reserved for locally defined coding schemes." ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "reserviert für lokale Tabellen" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Locally defined coding entity identifier.Retained for backward compatibility only as of v 2.8" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 13;
     fhir:Element.id [ fhir:value "2990" ];
     fhir:CodeSystem.concept.code [ fhir:value "NPI" ];
     fhir:CodeSystem.concept.display [ fhir:value "US National Provider Identifier" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Allows for the ability to designate organization identifier as a \"NPI\" assigned number (lab, any medical provider, can be a person or an organization)" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Use to identify assigning authority IDs, when an OID is not available.  Especially important in the CNN datatype. Namespace maintained and published in the US." ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 14;
     fhir:Element.id [ fhir:value "2991" ];
     fhir:CodeSystem.concept.code [ fhir:value "Random" ];
     fhir:CodeSystem.concept.display [ fhir:value "Random" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Usually a base64 encoded string of random bits.<p>Note: Random IDs are typically used for instance identifiers, rather than an identifier of an Assigning Authority that issues instance identifiers" ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "beliebig" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Usually a base64 encoded string of random bits.Retained for backward compatibility only as of v2.7; equivalent to a locally defined entity identifier scheme; use L. M, or N instead. Note: Random IDs are typically used for instance identifiers, rather than an identifier of an Assigning Authority that issues instance identifiers" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concCommentAsPub" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Retained for backward compatibility only as of v2.7; equivalent to a locally defined entity identifier scheme; use L. M, or N instead." ]     ], [
       fhir:index 2;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Retained for backward compatibility only as of v2.7; equivalent to a locally defined entity identifier scheme; use L. M, or N instead." ]     ], [
       fhir:index 3;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 15;
     fhir:Element.id [ fhir:value "2992" ];
     fhir:CodeSystem.concept.code [ fhir:value "URI" ];
     fhir:CodeSystem.concept.display [ fhir:value "Uniform Resource Identifier" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Uniform Resource Identifier" ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "URI" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 16;
     fhir:Element.id [ fhir:value "2993" ];
     fhir:CodeSystem.concept.code [ fhir:value "UUID" ];
     fhir:CodeSystem.concept.display [ fhir:value "Universal Unique Identifier" ];
     fhir:CodeSystem.concept.definition [ fhir:value "The DCE Universal Unique Identifier, in accordance with RFC 4122. Recommended format is 32 hexadecimal digits separated by hyphens, in the digit grouping 8-4-4-4-12" ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "UUID" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "The DCE Universal Unique Identifier, in accordance with RFC 4122. Recommended format is 32 hexadecimal digits separated by hyphens, in the digit grouping 8-4-4-4-12" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 17;
     fhir:Element.id [ fhir:value "2994" ];
     fhir:CodeSystem.concept.code [ fhir:value "x400" ];
     fhir:CodeSystem.concept.display [ fhir:value "X.400 MHS identifier" ];
     fhir:CodeSystem.concept.definition [ fhir:value "An X.400 MHS identifier. Recommended format is in accordance with RFC 1649" ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "X.400" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Recommended format is in accordance with RFC 1649" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ], [
     fhir:index 18;
     fhir:Element.id [ fhir:value "2995" ];
     fhir:CodeSystem.concept.code [ fhir:value "x500" ];
     fhir:CodeSystem.concept.display [ fhir:value "X500 directory Name" ];
     fhir:CodeSystem.concept.definition [ fhir:value "An X.500 directory name" ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "de" ];
       fhir:CodeSystem.concept.designation.use [
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra" ];
         fhir:Coding.code [ fhir:value "preferredForLanguage" ]       ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "X.500 Verzeichnis­name" ]     ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "A" ]     ]
  ]. # 

# - ontology header ------------------------------------------------------------

 a owl:Ontology;
  owl:imports fhir:fhir.ttl.