An observation form that determines parameters or attributes of an Act. Examples are the settings of a ventilator machine as parameters of a ventilator treatment act; the controls on dillution factors of a chemical analyzer as a parameter of a laboratory observation act; the settings of a physiologic measurement assembly (e.g., time skew) or the position of the body while measuring blood pressure.
Control variables are forms of observations because just as with clinical observations, the Observation.code determines the parameter and the Observation.value assigns the value. While control variables sometimes can be observed (by noting the control settings or an actually measured feedback loop) they are not primary observations, in the sense that a control variable without a primary act is of no use (e.g., it makes no sense to record a blood pressure position without recording a blood pressure, whereas it does make sense to record a systolic blood pressure without a diastolic blood pressure).
References
This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)
This value set includes codes based on the following rules:
http://terminology.hl7.org/CodeSystem/v3-ActCode
where concept is-a _ActControlVariableThis value set excludes codes based on the following rules:
http://terminology.hl7.org/CodeSystem/v3-ActCode
Code | Display | Definition |
_ActControlVariable | ActControlVariable | An observation form that determines parameters or attributes of an Act. Examples are the settings of a ventilator machine as parameters of a ventilator treatment act; the controls on dillution factors of a chemical analyzer as a parameter of a laboratory observation act; the settings of a physiologic measurement assembly (e.g., time skew) or the position of the body while measuring blood pressure. Control variables are forms of observations because just as with clinical observations, the Observation.code determines the parameter and the Observation.value assigns the value. While control variables sometimes can be observed (by noting the control settings or an actually measured feedback loop) they are not primary observations, in the sense that a control variable without a primary act is of no use (e.g., it makes no sense to record a blood pressure position without recording a blood pressure, whereas it does make sense to record a systolic blood pressure without a diastolic blood pressure). |
This value set contains 3 concepts
Expansion based on ActCode v6.1.0 (CodeSystem)
Code | System | Display | Definition |
AUTO | http://terminology.hl7.org/CodeSystem/v3-ActCode | auto-repeat permission | Specifies whether or not automatic repeat testing is to be initiated on specimens. |
ENDC | http://terminology.hl7.org/CodeSystem/v3-ActCode | endogenous content | A baseline value for the measured test that is inherently contained in the diluent. In the calculation of the actual result for the measured test, this baseline value is normally considered. |
REFLEX | http://terminology.hl7.org/CodeSystem/v3-ActCode | reflex permission | Specifies whether or not further testing may be automatically or manually initiated on specimens. |
_ECGControlVariable | http://terminology.hl7.org/CodeSystem/v3-ActCode | ECGControlVariable |
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |
History
Date | Action | Custodian | Author | Comment |
2020-05-06 | revise | Vocabulary WG | Ted Klein | Migrated to the UTG maintenance environment and publishing tooling. |
2014-03-26 | revise | 2014T1_2014-03-26_001283 (RIM release ID) | Vocabulary (Woody Beeler) (no record of original request) | Lock all vaue sets untouched since 2014-03-26 to trackingId 2014T1_2014_03_26 |