HL7 Terminology (THO)
4.0.0 - Publication International flag

This page is part of the HL7 Terminology (v4.0.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions

CodeSystem: rootCause

Official URL: http://terminology.hl7.org/CodeSystem/v2-0914 Version: 2.1.0
Active as of 2019-12-01 Responsible: HL7, Inc Computable Name: RootCause
Other Identifiers: : urn:oid:2.16.840.1.113883.18.421

Copyright/Legal: Copyright HL7. Licensed under creative commons public domain

Code system of concepts specifying the root cause. Used in HL7 Version 2.x messaging in the OBX segment.

Underlying Master Code System for V2 table 0914 (Root Cause)

This Code system is referenced in the content logical definition of the following value sets:

Properties

CodeURLTypeDescription
statushttp://terminology.hl7.org/CodeSystem/utg-concept-properties#statuscodeStatus of the concept
deprecatedhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecatedcodeVersion of HL7 in which the code was deprecated
v2-concCommenthttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentstringV2 Concept Comment
v2-concCommentAsPubhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPubstringV2 Concept Comment As Published
HL7usageNoteshttp://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotesstringHL7 Concept Usage Notes

This code system http://terminology.hl7.org/CodeSystem/v2-0914 defines the following codes:

CodeDisplayDefinitionV2 Concept CommentV2 Concept Comment As PublishedHL7 Concept Usage Notes
AP Analysis ProcessAnalysis ProcessEnter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failureEnter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failureEnter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failure
IM Information ManagementInformation ManagementEnter (IM) when INFORMATION MANAGEMENT is the reason due to: • Database or Programming issues • Overriding of test results • Inaccurate calculations • Inaccurate flagging, reference ranges, units of measure • Incomplete/inaccurate transmission of test results • OtherEnter (IM) when INFORMATION MANAGEMENT is the reason due to: • Database or Programming issues • Overriding of test results • Inaccurate calculations • Inaccurate flagging, reference ranges, units of measure • Incomplete/inaccurate transmission of test results • OtherEnter (IM) when INFORMATION MANAGEMENT is the reason due to: • Database or Programming issues • Overriding of test results • Inaccurate calculations • Inaccurate flagging, reference ranges, units of measure • Incomplete/inaccurate transmission of test results • Other
L LaboratoryLaboratoryEnter (L) when LABORATORY is the reason due to:<p>• Data Entry error<p>• Testing/Technical error<p>• Repeat testing causing change to test resultEnter (L) when LABORATORY is the reason due to:<p>• Data Entry error<p>• Testing/Technical error<p>• Repeat testing causing change to test resultEnter (L) when LABORATORY is the reason due to: • Data Entry error • Testing/Technical error • Repeat testing causing change to test result
NA Not ApplicableNot ApplicableEnter (NA) when NOT-APPLICABLE is the reason due to: • If no revisions performed or • unable to determine reason for revision Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision)Enter (NA) when NOT-APPLICABLE is the reason due to: • If no revisions performed or • unable to determine reason for revision Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision)Enter (NA) when NOT-APPLICABLE is the reason due to: • If no revisions performed or • unable to determine reason for revision Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision)
PD Placer DataPlacer DataEnter (PD) when new or changed PLACER DATA information is the reason due to: • Changed patient demographics or • Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...)Enter (PD) when new or changed PLACER DATA information is the reason due to: • Changed patient demographics or • Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...)Enter (PD) when new or changed PLACER DATA information is the reason due to: • Changed patient demographics or • Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...)

History

DateActionCustodianAuthorComment
2020-05-06reviseVocabulary WGTed KleinMigrated to the UTG maintenance environment and publishing tooling.