HL7 Terminology (THO)
3.1.0 - Publication International flag

This page is part of the HL7 Terminology (v3.1.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions

ValueSet: ActRelationshipEndsBeforeEnd

Official URL: http://terminology.hl7.org/ValueSet/v3-ActRelationshipEndsBeforeEnd Version: 2.0.0
Active as of 2014-03-26 Computable Name: ActRelationshipEndsBeforeEnd
Other Identifiers: : urn:oid:2.16.840.1.113883.1.11.20452

The source Act ends after the end of the target Act (i.e. if we say “ActOne EBE ActTwo”, it means that ActOne ends before the end of ActTwo, therefore ActOne is the source and ActTwo is the target).

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

 

Expansion

This value set contains 6 concepts

Expansion based on ActRelationshipType v3.1.0 (CodeSystem)

All codes in this table are from the system http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType

LvlCodeDisplayDefinition
0EBEends before end ofThe source Act ends before the end of the target Act (i.e. if we say "ActOne EBE ActTwo", it means that ActOne ends before the end of ActTwo, therefore ActOne is the source and ActTwo is the target). *UsageNote:* Inverse code is **EAE**
1  SBSEBEstarts before start of, ends before end ofThe source Act starts before the start of the target Act, and ends before the end of the target Act. *UsageNote:* Inverse code is **SASEAE**
2    SBSEASEBEcontains start of, ends before end ofThe source Act contains the start of the target Act, and ends before the end of the target Act. *UsageNote:* Inverse code is **SASSBEEAS**
2    EBSORECWSends before or concurrent with start ofA relationship in which the source act's effective time ends before or concurrent with the start of the target act's effective time. *Usage Note:* Inverse code is EASORECWS
3      ECWSends concurrent with start ofThe source Act ends when the target act starts (i.e. if we say "ActOne ECWS ActTwo", it means that ActOne ends when ActTwo starts, therefore ActOne is the source and ActTwo is the target). *UsageNote:* Inverse code is **SCWE**
3      EBSends before start ofA relationship in which the source act ends before the target act starts. *UsageNote:* Inverse code is **SAE**

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code

History

DateActionCustodianAuthorComment
2020-05-06reviseVocabulary WGTed KleinMigrated to the UTG maintenance environment and publishing tooling.
2014-03-26revise2014T1_2014-03-26_001283 (RIM release ID)Vocabulary (Woody Beeler) (no record of original request)Lock all vaue sets untouched since 2014-03-26 to trackingId 2014T1_2014_03_26