HL7 Terminology (THO)
3.1.0 - Publication
This page is part of the HL7 Terminology (v3.1.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions
Active as of 2019-12-01 |
{
"resourceType" : "CodeSystem",
"id" : "v2-0369",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Properties</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>URL</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>code</td><td>Status of the concept</td></tr><tr><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>code</td><td>Version of HL7 in which the code was deprecated</td></tr><tr><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>string</td><td>V2 Concept Comment</td></tr></table><p>This code system http://terminology.hl7.org/CodeSystem/v2-0369 defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Concept Comment</b></td></tr><tr><td style=\"white-space:nowrap\">B<a name=\"v2-0369-B\"> </a></td><td>Blind Sample</td><td>Used to test the validity of the measurement process, where the composition of the sample is unknown except to the person submitting it.</td><td/></tr><tr><td style=\"white-space:nowrap\">C<a name=\"v2-0369-C\"> </a></td><td>Calibrator</td><td>Used for initial setting of calibration of the instrument.</td><td/></tr><tr><td style=\"white-space:nowrap\">E<a name=\"v2-0369-E\"> </a></td><td>Electronic QC</td><td>Used with manufactured reference providing signals that simulate QC results</td><td/></tr><tr><td style=\"white-space:nowrap\">F<a name=\"v2-0369-F\"> </a></td><td>Filler Organization Proficiency</td><td>Specimen used for testing proficiency of the organization performing the testing (Filler).</td><td/></tr><tr><td style=\"white-space:nowrap\">G<a name=\"v2-0369-G\"> </a></td><td>Group</td><td>Used when solid specimens consist of multiple individual elements that are not individually identified but can be separated again into the original specimens. The identifiers of the original specimens may be tracked.</td><td/></tr><tr><td style=\"white-space:nowrap\">H<a name=\"v2-0369-H\"> </a></td><td>Historical Specimen</td><td>This identifies a parent specimen to the specimen that is submitted for testing</td><td>The order of specimen processing can be derived from the SPM-3 value in all SPM segments in the message. More than one historical SPM can be submitted, each SPM describes one step in the derivation process of the specimen submitted for testing.</td></tr><tr><td style=\"white-space:nowrap\">L<a name=\"v2-0369-L\"> </a></td><td>Pool</td><td>Used when aliquots of liquid individual specimens are combined to form a single specimen representing all of the components that are not individually identified. The identifiers of the original specimens may be tracked.</td><td/></tr><tr><td style=\"white-space:nowrap\">O<a name=\"v2-0369-O\"> </a></td><td>Operator Proficiency</td><td>Specimen used for testing Operator Proficiency.</td><td/></tr><tr><td style=\"white-space:nowrap\">P<a name=\"v2-0369-P\"> </a></td><td>Patient</td><td>Used for any patient sample.</td><td>If the component is not valued (blank) this represents the default meaning.</td></tr><tr><td style=\"white-space:nowrap\">Q<a name=\"v2-0369-Q\"> </a></td><td>Control specimen</td><td>Used when specimen is the control specimen (either positive or negative).</td><td/></tr><tr><td style=\"white-space:nowrap\">R<a name=\"v2-0369-R\"> </a></td><td>Replicate (of patient sample as a control)</td><td>Used when a patient sample is re-run as a control for a repeat test.</td><td/></tr><tr><td style=\"white-space:nowrap\">V<a name=\"v2-0369-V\"> </a></td><td>Verifying Calibrator</td><td>Used for periodic calibration checks.</td><td/></tr></table></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "oo"
}
],
"url" : "http://terminology.hl7.org/CodeSystem/v2-0369",
"identifier" : [
{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.18.227"
}
],
"version" : "2.2.0",
"name" : "SpecimenRole",
"title" : "specimenRole",
"status" : "active",
"experimental" : false,
"date" : "2019-12-01",
"publisher" : "HL7, Inc",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/"
}
]
}
],
"description" : "HL7-defined code system of concepts that identify the role of a sample. Used in HL7 Version 2.x messaging in the Specimen (SPM) and Observation Request (OBR) segments.",
"purpose" : "Underlying Master Code System for V2 table 0369 (Specimen Role)",
"copyright" : "Copyright HL7. Licensed under creative commons public domain",
"caseSensitive" : true,
"valueSet" : "http://terminology.hl7.org/ValueSet/v2-0369",
"hierarchyMeaning" : "is-a",
"compositional" : false,
"versionNeeded" : false,
"content" : "complete",
"property" : [
{
"code" : "status",
"uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status",
"description" : "Status of the concept",
"type" : "code"
},
{
"code" : "deprecated",
"uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated",
"description" : "Version of HL7 in which the code was deprecated",
"type" : "code"
},
{
"code" : "v2-concComment",
"uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment",
"description" : "V2 Concept Comment",
"type" : "string"
}
],
"concept" : [
{
"id" : "3714",
"code" : "B",
"display" : "Blind Sample",
"definition" : "Used to test the validity of the measurement process, where the composition of the sample is unknown except to the person submitting it.",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3715",
"code" : "C",
"display" : "Calibrator",
"definition" : "Used for initial setting of calibration of the instrument.",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3716",
"code" : "E",
"display" : "Electronic QC",
"definition" : "Used with manufactured reference providing signals that simulate QC results",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3717",
"code" : "F",
"display" : "Filler Organization Proficiency",
"definition" : "Specimen used for testing proficiency of the organization performing the testing (Filler).",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3718",
"code" : "G",
"display" : "Group",
"definition" : "Used when solid specimens consist of multiple individual elements that are not individually identified but can be separated again into the original specimens. The identifiers of the original specimens may be tracked.",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3719",
"code" : "H",
"display" : "Historical Specimen",
"definition" : "This identifies a parent specimen to the specimen that is submitted for testing",
"property" : [
{
"code" : "v2-concComment",
"valueString" : "The order of specimen processing can be derived from the SPM-3 value in all SPM segments in the message. More than one historical SPM can be submitted, each SPM describes one step in the derivation process of the specimen submitted for testing."
},
{
"code" : "status",
"valueCode" : "N"
}
]
},
{
"id" : "3720",
"code" : "L",
"display" : "Pool",
"definition" : "Used when aliquots of liquid individual specimens are combined to form a single specimen representing all of the components that are not individually identified. The identifiers of the original specimens may be tracked.",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3721",
"code" : "O",
"display" : "Operator Proficiency",
"definition" : "Specimen used for testing Operator Proficiency.",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3722",
"code" : "P",
"display" : "Patient",
"definition" : "Used for any patient sample.",
"property" : [
{
"code" : "v2-concComment",
"valueString" : "If the component is not valued (blank) this represents the default meaning."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3723",
"code" : "Q",
"display" : "Control specimen",
"definition" : "Used when specimen is the control specimen (either positive or negative).",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3724",
"code" : "R",
"display" : "Replicate (of patient sample as a control)",
"definition" : "Used when a patient sample is re-run as a control for a repeat test.",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3725",
"code" : "V",
"display" : "Verifying Calibrator",
"definition" : "Used for periodic calibration checks.",
"property" : [
{
"code" : "status",
"valueCode" : "A"
}
]
}
]
}