@prefix fhir: . @prefix owl: . @prefix rdfs: . @prefix xsd: . # - resource ------------------------------------------------------------------- a fhir:CodeSystem; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "v2-0949"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "

Properties

CodeURLDescriptionType
statushttp://terminology.hl7.org/CodeSystem/utg-concept-properties#statusStatus of the conceptcode
deprecatedhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecatedVersion of HL7 in which the code was deprecatedcode
v2-concCommenthttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentV2 Concept Commentstring
HL7usageNoteshttp://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotesHL7 Concept Usage Notesstring

This code system http://terminology.hl7.org/CodeSystem/v2-0949 defines the following codes:

CodeDisplayDefinitionV2 Concept CommentHL7 Concept Usage Notes
CO CostOrder changed based on costIn an order replacement context, this would accompany proposal of a similar but lower cost order
ST Specimen TypeIncorrect specimen type submitted for the requested testOrder placer may accept, cancel and replace, or choose other testing.Recommend testing that can use the submitted specimen type
SV Specimen VolumeProvided specimen volume inadequate for testingThe question is how to use the available specimen. The Order Placer may choose a different subset of tests.Recommend a subset of ordered tests appropriate for volume
UN Unavailable testRequested test not availableIn an order replacement context, an alternative might be proposed.
" ]; fhir:DomainResource.extension [ fhir:index 0; fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg" ]; fhir:Extension.valueCode [ fhir:value "oo" ] ]; fhir:CodeSystem.url [ fhir:value "http://terminology.hl7.org/CodeSystem/v2-0949"]; fhir:CodeSystem.identifier [ fhir:index 0; fhir:Identifier.system [ fhir:value "urn:ietf:rfc:3986" ]; fhir:Identifier.value [ fhir:value "urn:oid:2.16.840.1.113883.18.449" ] ]; fhir:CodeSystem.version [ fhir:value "2.1.0"]; fhir:CodeSystem.name [ fhir:value "OrderControlCodeReason"]; fhir:CodeSystem.title [ fhir:value "orderControlCodeReason"]; fhir:CodeSystem.status [ fhir:value "active"]; fhir:CodeSystem.experimental [ fhir:value "false"^^xsd:boolean]; fhir:CodeSystem.date [ fhir:value "2019-12-01"^^xsd:date]; fhir:CodeSystem.publisher [ fhir:value "HL7, Inc"]; fhir:CodeSystem.contact [ fhir:index 0; fhir:ContactDetail.telecom [ fhir:index 0; fhir:ContactPoint.system [ fhir:value "url" ]; fhir:ContactPoint.value [ fhir:value "http://www.hl7.org/" ] ] ]; fhir:CodeSystem.description [ fhir:value "HL7-defined code system of concepts that describe reasons for the chosen order control codes. Used in HL7 Version 2 messaging in the ORC segment."]; fhir:CodeSystem.purpose [ fhir:value "Underlying Master Code System for V2 table 0949 (Order Control Code Reason)"]; fhir:CodeSystem.copyright [ fhir:value "Copyright HL7. Licensed under creative commons public domain"]; fhir:CodeSystem.caseSensitive [ fhir:value "true"^^xsd:boolean]; fhir:CodeSystem.valueSet [ fhir:value "http://terminology.hl7.org/ValueSet/v2-0949"; fhir:link ]; fhir:CodeSystem.hierarchyMeaning [ fhir:value "is-a"]; fhir:CodeSystem.compositional [ fhir:value "false"^^xsd:boolean]; fhir:CodeSystem.versionNeeded [ fhir:value "false"^^xsd:boolean]; fhir:CodeSystem.content [ fhir:value "complete"]; fhir:CodeSystem.property [ fhir:index 0; fhir:CodeSystem.property.code [ fhir:value "status" ]; fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status" ]; fhir:CodeSystem.property.description [ fhir:value "Status of the concept" ]; fhir:CodeSystem.property.type [ fhir:value "code" ] ], [ fhir:index 1; fhir:CodeSystem.property.code [ fhir:value "deprecated" ]; fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated" ]; fhir:CodeSystem.property.description [ fhir:value "Version of HL7 in which the code was deprecated" ]; fhir:CodeSystem.property.type [ fhir:value "code" ] ], [ fhir:index 2; fhir:CodeSystem.property.code [ fhir:value "v2-concComment" ]; fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment" ]; fhir:CodeSystem.property.description [ fhir:value "V2 Concept Comment" ]; fhir:CodeSystem.property.type [ fhir:value "string" ] ], [ fhir:index 3; fhir:CodeSystem.property.code [ fhir:value "HL7usageNotes" ]; fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes" ]; fhir:CodeSystem.property.description [ fhir:value "HL7 Concept Usage Notes" ]; fhir:CodeSystem.property.type [ fhir:value "string" ] ]; fhir:CodeSystem.concept [ fhir:index 0; fhir:Element.id [ fhir:value "6769" ]; fhir:CodeSystem.concept.code [ fhir:value "CO" ]; fhir:CodeSystem.concept.display [ fhir:value "Cost" ]; fhir:CodeSystem.concept.definition [ fhir:value "Order changed based on cost" ]; fhir:CodeSystem.concept.property [ fhir:index 0; fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ]; fhir:CodeSystem.concept.property.valueString [ fhir:value "In an order replacement context, this would accompany proposal of a similar but lower cost order" ] ], [ fhir:index 1; fhir:CodeSystem.concept.property.code [ fhir:value "status" ]; fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ] ] ], [ fhir:index 1; fhir:Element.id [ fhir:value "6770" ]; fhir:CodeSystem.concept.code [ fhir:value "ST" ]; fhir:CodeSystem.concept.display [ fhir:value "Specimen Type" ]; fhir:CodeSystem.concept.definition [ fhir:value "Incorrect specimen type submitted for the requested test" ]; fhir:CodeSystem.concept.property [ fhir:index 0; fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ]; fhir:CodeSystem.concept.property.valueString [ fhir:value "Order placer may accept, cancel and replace, or choose other testing." ] ], [ fhir:index 1; fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ]; fhir:CodeSystem.concept.property.valueString [ fhir:value "Recommend testing that can use the submitted specimen type" ] ], [ fhir:index 2; fhir:CodeSystem.concept.property.code [ fhir:value "status" ]; fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ] ] ], [ fhir:index 2; fhir:Element.id [ fhir:value "6771" ]; fhir:CodeSystem.concept.code [ fhir:value "SV" ]; fhir:CodeSystem.concept.display [ fhir:value "Specimen Volume" ]; fhir:CodeSystem.concept.definition [ fhir:value "Provided specimen volume inadequate for testing" ]; fhir:CodeSystem.concept.property [ fhir:index 0; fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ]; fhir:CodeSystem.concept.property.valueString [ fhir:value "The question is how to use the available specimen. The Order Placer may choose a different subset of tests." ] ], [ fhir:index 1; fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ]; fhir:CodeSystem.concept.property.valueString [ fhir:value "Recommend a subset of ordered tests appropriate for volume" ] ], [ fhir:index 2; fhir:CodeSystem.concept.property.code [ fhir:value "status" ]; fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ] ] ], [ fhir:index 3; fhir:Element.id [ fhir:value "6772" ]; fhir:CodeSystem.concept.code [ fhir:value "UN" ]; fhir:CodeSystem.concept.display [ fhir:value "Unavailable test" ]; fhir:CodeSystem.concept.definition [ fhir:value "Requested test not available" ]; fhir:CodeSystem.concept.property [ fhir:index 0; fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ]; fhir:CodeSystem.concept.property.valueString [ fhir:value "In an order replacement context, an alternative might be proposed." ] ], [ fhir:index 1; fhir:CodeSystem.concept.property.code [ fhir:value "status" ]; fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ] ] ] . # - ontology header ------------------------------------------------------------ a owl:Ontology; owl:imports fhir:fhir.ttl . # -------------------------------------------------------------------------------------