HL7 Terminology
2.1.0 - Publication

This page is part of the HL7 Terminology (v2.1.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions

CodeSystem: natureOfServiceTestObservation

Summary

Defining URL:http://terminology.hl7.org/CodeSystem/v2-0174
Version:2.1.0
Name:NatureOfServiceTestObservation
Status:Active as of 2019-12-01
Definition:

Code system of concepts specifying an identification of a test battery, an entire functional procedure or study, a single test value (observation), multiple test batteries or functional procedures as an orderable unit (profile), or a single test value (observation) calculated from other independent observations, typically used as an indicator for Master Files. Used in HL7 Version 2.x messaging in the OM1 segment.

Publisher:HL7, Inc
Committee:Infrastructure And Messaging
Copyright:

Copyright HL7. Licensed under creative commons public domain

Content:Complete: All the concepts defined by the code system are included in the code system resource
OID:2.16.840.1.113883.18.90 (for OID based terminology systems)
Value Set:http://terminology.hl7.org/ValueSet/v2-0174 ( is the value set for all codes in this code system)
Source Resource:XML / JSON / Turtle

This Code system is referenced in the content logical definition of the following value sets:

Properties

CodeURLDescriptionType
statushttp://terminology.hl7.org/CodeSystem/utg-concept-properties#statusStatus of the conceptcode
deprecatedhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecatedVersion of HL7 in which the code was deprecatedcode
v2-concCommenthttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentV2 Concept Commentstring
v2-concCommentAsPubhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPubV2 Concept Comment As Publishedstring

This code system http://terminology.hl7.org/CodeSystem/v2-0174 defines the following codes:

CodeDisplayDefinitionV2 Concept CommentV2 Concept Comment As Published
P Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimenProfile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimencan be associated with one or more OM4 (specimen) segments<p>See comment for value Scan be associated with one or more OM4 (specimen) segments<p>See comment for value S
F Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimensFunctional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimenscan be associated with one or more OM4 (specimen) segments<p>See comment for value Scan be associated with one or more OM4 (specimen) segments<p>See comment for value S
A Atomic service/test/observation (test code or treatment code)Atomic service/test/observation (test code or treatment code)can be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segmentscan be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segments
S Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes)<p>This set indicates that the code being described is used to order multiple service/test/observation bSuperset—a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes) This set indicates that the code being described is used to order multiple service/test/observation batteries. For example, a client who routinely orders a CBC, a differential, and a thyroxine as an outpatient profile might use a single, special code to order all three test batteries, instead of having to submit three separate order codes.can be associated with one or more OM4 (specimen) segments Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observationcan be associated with one or more OM4 (specimen) segments Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observation
C Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output)Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output)can be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segmentcan be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segment

Additional Language Displays

CodeDeutsch (German, de)
PBatterieanordnung
FFunktionstest
AEinzeluntersuchung
SLatte von mehreren Batterieanforderungen (Aufnahmelatte)
CBerechnetes Einzelergebnis

History

DateActionAuthorCustodianComment
2020-05-06reviseTed KleinVocabulary WGMigrated to the UTG maintenance environment and publishing tooling.