HL7 Terminology
1.0.0 - Publication

This page is part of the HL7 Terminology (v1.0.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions

reasonForStudy - TTL Representation

(back to description)

Raw ttl

Source view

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CodeSystem;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "v2-0951"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2>reasonForStudy</h2><div><p>HL7-defined code system of concepts that provide additional information to the universal service identifier on why a test, study or review was ordered. Initial values are to support the IHE LCC LAB-7 transaction.</p>\n</div><p><b>Copyright Statement:</b> Copyright HL7. Licensed under creative commons public domain</p><p><b>Properties</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>URL</b></td><td><b>Description</b></td><td><b>Type</b></td></tr><tr><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>Status of the concept</td><td>code</td></tr><tr><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>Version of HL7 in which the code was deprecated</td><td>code</td></tr><tr><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>V2 Concept Comment</td><td>string</td></tr><tr><td>HL7usageNotes</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes</td><td>HL7 Concept Usage Notes</td><td>string</td></tr></table><p>This code system http://terminology.hl7.org/CodeSystem/v2-0951 defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Table Status</b></td><td><b>V2 Concept Comment</b></td><td><b>HL7 Concept Usage Notes</b></td></tr><tr><td style=\"white-space:nowrap\">BS<a name=\"v2-0951-BS\"> </a></td><td>Bank residual specimen</td><td>Requests that the specimen should be stored long term</td><td>N</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">CR<a name=\"v2-0951-CR\"> </a></td><td>Confirm results value</td><td>Requests verification of previously reported results</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">FP<a name=\"v2-0951-FP\"> </a></td><td>Store residual specimen pending follow up</td><td>Requests that the specimen should be saved for a short duration until follow up is completed</td><td>N</td><td>Provides instructions for Specimen storage</td><td/></tr><tr><td style=\"white-space:nowrap\">IN<a name=\"v2-0951-IN\"> </a></td><td>Interpret results</td><td>Requests interpretation of previously reported results</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">IR<a name=\"v2-0951-IR\"> </a></td><td>Review clinically inconsistent results</td><td>Requests comparison of previously reported results amongst themselves</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">IT<a name=\"v2-0951-IT\"> </a></td><td>Incorrect test performed</td><td>For process improvement work this code can be used to identify when an incorrect test was performed for the target order</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">OP<a name=\"v2-0951-OP\"> </a></td><td>Test ordering problem</td><td>For process improvement work this code can be used to identify orders and the respective results, where problems occurred during ordering</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">PI<a name=\"v2-0951-PI\"> </a></td><td>Patient identification problem</td><td>For process improvement work this code can be used to identify when a patient identification issue has occurred on the target order</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">SI<a name=\"v2-0951-SI\"> </a></td><td>Suspected interference</td><td>Requests verification of previously reported results due to suspected interference</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">SP<a name=\"v2-0951-SP\"> </a></td><td>Sampling problem</td><td>For process improvement work this code can be used to identify orders, where problems occurred during sample collection</td><td>R</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">TP<a name=\"v2-0951-TP\"> </a></td><td>Specimen transport problem</td><td>For process improvement work this code can be used to identify orders, where problems occurred during sample transport</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">TT<a name=\"v2-0951-TT\"> </a></td><td>Turnaround time problem</td><td>For process improvement work this code can be used to identify results with excessive reporting delay</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr><tr><td style=\"white-space:nowrap\">XR<a name=\"v2-0951-XR\"> </a></td><td>Incorrect results</td><td>For process improvement work this code can be used to identify when incorrect result were reported for the target order</td><td>N</td><td/><td>Used to indicate why review is requested</td></tr></table></div>"
  ];
  fhir:DomainResource.extension [
     fhir:index 0;
     fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg" ];
     fhir:Extension.valueCode [ fhir:value "oo" ]
  ];
  fhir:CodeSystem.url [ fhir:value "http://terminology.hl7.org/CodeSystem/v2-0951"];
  fhir:CodeSystem.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "urn:ietf:rfc:3986" ];
     fhir:Identifier.value [ fhir:value "urn:oid:2.16.840.1.113883.18.451" ]
  ];
  fhir:CodeSystem.version [ fhir:value "2.1.0"];
  fhir:CodeSystem.name [ fhir:value "ReasonForStudy"];
  fhir:CodeSystem.title [ fhir:value "reasonForStudy"];
  fhir:CodeSystem.status [ fhir:value "active"];
  fhir:CodeSystem.experimental [ fhir:value "false"^^xsd:boolean];
  fhir:CodeSystem.date [ fhir:value "2019-12-01T00:00:00-05:00"^^xsd:dateTime];
  fhir:CodeSystem.publisher [ fhir:value "HL7, Inc"];
  fhir:CodeSystem.contact [
     fhir:index 0;
     fhir:ContactDetail.telecom [
       fhir:index 0;
       fhir:ContactPoint.system [ fhir:value "url" ];
       fhir:ContactPoint.value [ fhir:value "http://www.hl7.org/" ]     ]
  ];
  fhir:CodeSystem.description [ fhir:value "HL7-defined code system of concepts that provide additional information to the universal service identifier on why a test, study or review was ordered. Initial values are to support the IHE LCC LAB-7 transaction."];
  fhir:CodeSystem.purpose [ fhir:value "Underlying Master Code System for V2 table 0951 (Reason for Study)"];
  fhir:CodeSystem.copyright [ fhir:value "Copyright HL7. Licensed under creative commons public domain"];
  fhir:CodeSystem.caseSensitive [ fhir:value "true"^^xsd:boolean];
  fhir:CodeSystem.valueSet [
     fhir:value "http://terminology.hl7.org/ValueSet/v2-0951";
     fhir:link <http://terminology.hl7.org/ValueSet/v2-0951>
  ];
  fhir:CodeSystem.hierarchyMeaning [ fhir:value "is-a"];
  fhir:CodeSystem.compositional [ fhir:value "false"^^xsd:boolean];
  fhir:CodeSystem.versionNeeded [ fhir:value "false"^^xsd:boolean];
  fhir:CodeSystem.content [ fhir:value "complete"];
  fhir:CodeSystem.property [
     fhir:index 0;
     fhir:CodeSystem.property.code [ fhir:value "status" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status" ];
     fhir:CodeSystem.property.description [ fhir:value "Status of the concept" ];
     fhir:CodeSystem.property.type [ fhir:value "code" ]
  ], [
     fhir:index 1;
     fhir:CodeSystem.property.code [ fhir:value "deprecated" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated" ];
     fhir:CodeSystem.property.description [ fhir:value "Version of HL7 in which the code was deprecated" ];
     fhir:CodeSystem.property.type [ fhir:value "code" ]
  ], [
     fhir:index 2;
     fhir:CodeSystem.property.code [ fhir:value "v2-concComment" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment" ];
     fhir:CodeSystem.property.description [ fhir:value "V2 Concept Comment" ];
     fhir:CodeSystem.property.type [ fhir:value "string" ]
  ], [
     fhir:index 3;
     fhir:CodeSystem.property.code [ fhir:value "HL7usageNotes" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes" ];
     fhir:CodeSystem.property.description [ fhir:value "HL7 Concept Usage Notes" ];
     fhir:CodeSystem.property.type [ fhir:value "string" ]
  ];
  fhir:CodeSystem.concept [
     fhir:index 0;
     fhir:Element.id [ fhir:value "6775" ];
     fhir:CodeSystem.concept.code [ fhir:value "BS" ];
     fhir:CodeSystem.concept.display [ fhir:value "Bank residual specimen" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Requests that the specimen should be stored long term" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 1;
     fhir:Element.id [ fhir:value "6776" ];
     fhir:CodeSystem.concept.code [ fhir:value "CR" ];
     fhir:CodeSystem.concept.display [ fhir:value "Confirm results value" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Requests verification of previously reported results" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 2;
     fhir:Element.id [ fhir:value "6777" ];
     fhir:CodeSystem.concept.code [ fhir:value "FP" ];
     fhir:CodeSystem.concept.display [ fhir:value "Store residual specimen pending follow up" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Requests that the specimen should be saved for a short duration until follow up is completed" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Provides instructions for Specimen storage" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 3;
     fhir:Element.id [ fhir:value "6778" ];
     fhir:CodeSystem.concept.code [ fhir:value "IN" ];
     fhir:CodeSystem.concept.display [ fhir:value "Interpret results" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Requests interpretation of previously reported results" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 4;
     fhir:Element.id [ fhir:value "6779" ];
     fhir:CodeSystem.concept.code [ fhir:value "IR" ];
     fhir:CodeSystem.concept.display [ fhir:value "Review clinically inconsistent results" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Requests comparison of previously reported results amongst themselves" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 5;
     fhir:Element.id [ fhir:value "6780" ];
     fhir:CodeSystem.concept.code [ fhir:value "IT" ];
     fhir:CodeSystem.concept.display [ fhir:value "Incorrect test performed" ];
     fhir:CodeSystem.concept.definition [ fhir:value "For process improvement work this code can be used to identify when an incorrect test was performed for the target order" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 6;
     fhir:Element.id [ fhir:value "6781" ];
     fhir:CodeSystem.concept.code [ fhir:value "OP" ];
     fhir:CodeSystem.concept.display [ fhir:value "Test ordering problem" ];
     fhir:CodeSystem.concept.definition [ fhir:value "For process improvement work this code can be used to identify orders and the respective results, where problems occurred during ordering" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 7;
     fhir:Element.id [ fhir:value "6782" ];
     fhir:CodeSystem.concept.code [ fhir:value "PI" ];
     fhir:CodeSystem.concept.display [ fhir:value "Patient identification problem" ];
     fhir:CodeSystem.concept.definition [ fhir:value "For process improvement work this code can be used to identify when a patient identification issue has occurred on the target order" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 8;
     fhir:Element.id [ fhir:value "6783" ];
     fhir:CodeSystem.concept.code [ fhir:value "SI" ];
     fhir:CodeSystem.concept.display [ fhir:value "Suspected interference" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Requests verification of previously reported results due to suspected interference" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 9;
     fhir:Element.id [ fhir:value "6784" ];
     fhir:CodeSystem.concept.code [ fhir:value "SP" ];
     fhir:CodeSystem.concept.display [ fhir:value "Sampling problem" ];
     fhir:CodeSystem.concept.definition [ fhir:value "For process improvement work this code can be used to identify orders, where problems occurred during sample collection" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "R" ]     ]
  ], [
     fhir:index 10;
     fhir:Element.id [ fhir:value "6785" ];
     fhir:CodeSystem.concept.code [ fhir:value "TP" ];
     fhir:CodeSystem.concept.display [ fhir:value "Specimen transport problem" ];
     fhir:CodeSystem.concept.definition [ fhir:value "For process improvement work this code can be used to identify orders, where problems occurred during sample transport" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 11;
     fhir:Element.id [ fhir:value "6786" ];
     fhir:CodeSystem.concept.code [ fhir:value "TT" ];
     fhir:CodeSystem.concept.display [ fhir:value "Turnaround time problem" ];
     fhir:CodeSystem.concept.definition [ fhir:value "For process improvement work this code can be used to identify results with excessive reporting delay" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 12;
     fhir:Element.id [ fhir:value "6787" ];
     fhir:CodeSystem.concept.code [ fhir:value "XR" ];
     fhir:CodeSystem.concept.display [ fhir:value "Incorrect results" ];
     fhir:CodeSystem.concept.definition [ fhir:value "For process improvement work this code can be used to identify when incorrect result were reported for the target order" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Used to indicate why review is requested" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ].

# - ontology header ------------------------------------------------------------

 a owl:Ontology;
  owl:imports fhir:fhir.ttl.