HL7 Terminology
1.0.0 - Publication

This page is part of the HL7 Terminology (v1.0.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions

orderControlCodeReason - TTL Representation

(back to description)

Raw ttl

Source view

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CodeSystem;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "v2-0949"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2>orderControlCodeReason</h2><div><p>HL7-defined code system of concepts that describe reasons for the chosen order control codes. Used in HL7 Version 2 messaging in the ORC segment.</p>\n</div><p><b>Copyright Statement:</b> Copyright HL7. Licensed under creative commons public domain</p><p><b>Properties</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>URL</b></td><td><b>Description</b></td><td><b>Type</b></td></tr><tr><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>Status of the concept</td><td>code</td></tr><tr><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>Version of HL7 in which the code was deprecated</td><td>code</td></tr><tr><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>V2 Concept Comment</td><td>string</td></tr><tr><td>HL7usageNotes</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes</td><td>HL7 Concept Usage Notes</td><td>string</td></tr></table><p>This code system http://terminology.hl7.org/CodeSystem/v2-0949 defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Table Status</b></td><td><b>V2 Concept Comment</b></td><td><b>HL7 Concept Usage Notes</b></td></tr><tr><td style=\"white-space:nowrap\">CO<a name=\"v2-0949-CO\"> </a></td><td>Cost</td><td>Order changed based on cost</td><td>N</td><td>In an order replacement context, this would accompany proposal of a similar but lower cost order</td><td/></tr><tr><td style=\"white-space:nowrap\">ST<a name=\"v2-0949-ST\"> </a></td><td>Specimen Type</td><td>Incorrect specimen type submitted for the requested test</td><td>N</td><td>Order placer may accept, cancel and replace, or choose other testing.</td><td>Recommend testing that can use the submitted specimen type</td></tr><tr><td style=\"white-space:nowrap\">SV<a name=\"v2-0949-SV\"> </a></td><td>Specimen Volume</td><td>Provided specimen volume inadequate for testing</td><td>N</td><td>The question is how to use the available specimen. The Order Placer may choose a different subset of tests.</td><td>Recommend a subset of ordered tests appropriate for volume</td></tr><tr><td style=\"white-space:nowrap\">UN<a name=\"v2-0949-UN\"> </a></td><td>Unavailable test</td><td>Requested test not available</td><td>N</td><td>In an order replacement context, an alternative might be proposed.</td><td/></tr></table></div>"
  ];
  fhir:DomainResource.extension [
     fhir:index 0;
     fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg" ];
     fhir:Extension.valueCode [ fhir:value "oo" ]
  ];
  fhir:CodeSystem.url [ fhir:value "http://terminology.hl7.org/CodeSystem/v2-0949"];
  fhir:CodeSystem.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "urn:ietf:rfc:3986" ];
     fhir:Identifier.value [ fhir:value "urn:oid:2.16.840.1.113883.18.449" ]
  ];
  fhir:CodeSystem.version [ fhir:value "2.1.0"];
  fhir:CodeSystem.name [ fhir:value "OrderControlCodeReason"];
  fhir:CodeSystem.title [ fhir:value "orderControlCodeReason"];
  fhir:CodeSystem.status [ fhir:value "active"];
  fhir:CodeSystem.experimental [ fhir:value "false"^^xsd:boolean];
  fhir:CodeSystem.date [ fhir:value "2019-12-01T00:00:00-05:00"^^xsd:dateTime];
  fhir:CodeSystem.publisher [ fhir:value "HL7, Inc"];
  fhir:CodeSystem.contact [
     fhir:index 0;
     fhir:ContactDetail.telecom [
       fhir:index 0;
       fhir:ContactPoint.system [ fhir:value "url" ];
       fhir:ContactPoint.value [ fhir:value "http://www.hl7.org/" ]     ]
  ];
  fhir:CodeSystem.description [ fhir:value "HL7-defined code system of concepts that describe reasons for the chosen order control codes. Used in HL7 Version 2 messaging in the ORC segment."];
  fhir:CodeSystem.purpose [ fhir:value "Underlying Master Code System for V2 table 0949 (Order Control Code Reason)"];
  fhir:CodeSystem.copyright [ fhir:value "Copyright HL7. Licensed under creative commons public domain"];
  fhir:CodeSystem.caseSensitive [ fhir:value "true"^^xsd:boolean];
  fhir:CodeSystem.valueSet [
     fhir:value "http://terminology.hl7.org/ValueSet/v2-0949";
     fhir:link <http://terminology.hl7.org/ValueSet/v2-0949>
  ];
  fhir:CodeSystem.hierarchyMeaning [ fhir:value "is-a"];
  fhir:CodeSystem.compositional [ fhir:value "false"^^xsd:boolean];
  fhir:CodeSystem.versionNeeded [ fhir:value "false"^^xsd:boolean];
  fhir:CodeSystem.content [ fhir:value "complete"];
  fhir:CodeSystem.property [
     fhir:index 0;
     fhir:CodeSystem.property.code [ fhir:value "status" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status" ];
     fhir:CodeSystem.property.description [ fhir:value "Status of the concept" ];
     fhir:CodeSystem.property.type [ fhir:value "code" ]
  ], [
     fhir:index 1;
     fhir:CodeSystem.property.code [ fhir:value "deprecated" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated" ];
     fhir:CodeSystem.property.description [ fhir:value "Version of HL7 in which the code was deprecated" ];
     fhir:CodeSystem.property.type [ fhir:value "code" ]
  ], [
     fhir:index 2;
     fhir:CodeSystem.property.code [ fhir:value "v2-concComment" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment" ];
     fhir:CodeSystem.property.description [ fhir:value "V2 Concept Comment" ];
     fhir:CodeSystem.property.type [ fhir:value "string" ]
  ], [
     fhir:index 3;
     fhir:CodeSystem.property.code [ fhir:value "HL7usageNotes" ];
     fhir:CodeSystem.property.uri [ fhir:value "http://terminology.hl7.org/CodeSystem/utg-concept-properties#HL7usageNotes" ];
     fhir:CodeSystem.property.description [ fhir:value "HL7 Concept Usage Notes" ];
     fhir:CodeSystem.property.type [ fhir:value "string" ]
  ];
  fhir:CodeSystem.concept [
     fhir:index 0;
     fhir:Element.id [ fhir:value "6769" ];
     fhir:CodeSystem.concept.code [ fhir:value "CO" ];
     fhir:CodeSystem.concept.display [ fhir:value "Cost" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Order changed based on cost" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "In an order replacement context, this would accompany proposal of a similar but lower cost order" ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 1;
     fhir:Element.id [ fhir:value "6770" ];
     fhir:CodeSystem.concept.code [ fhir:value "ST" ];
     fhir:CodeSystem.concept.display [ fhir:value "Specimen Type" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Incorrect specimen type submitted for the requested test" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Order placer may accept, cancel and replace, or choose other testing." ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Recommend testing that can use the submitted specimen type" ]     ], [
       fhir:index 2;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 2;
     fhir:Element.id [ fhir:value "6771" ];
     fhir:CodeSystem.concept.code [ fhir:value "SV" ];
     fhir:CodeSystem.concept.display [ fhir:value "Specimen Volume" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Provided specimen volume inadequate for testing" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "The question is how to use the available specimen. The Order Placer may choose a different subset of tests." ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "HL7usageNotes" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "Recommend a subset of ordered tests appropriate for volume" ]     ], [
       fhir:index 2;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ], [
     fhir:index 3;
     fhir:Element.id [ fhir:value "6772" ];
     fhir:CodeSystem.concept.code [ fhir:value "UN" ];
     fhir:CodeSystem.concept.display [ fhir:value "Unavailable test" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Requested test not available" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "v2-concComment" ];
       fhir:CodeSystem.concept.property.valueString [ fhir:value "In an order replacement context, an alternative might be proposed." ]     ], [
       fhir:index 1;
       fhir:CodeSystem.concept.property.code [ fhir:value "status" ];
       fhir:CodeSystem.concept.property.valueCode [ fhir:value "N" ]     ]
  ].

# - ontology header ------------------------------------------------------------

 a owl:Ontology;
  owl:imports fhir:fhir.ttl.