cycleType

Summary

Defining URL:http://terminology.hl7.org/CodeSystem/v2-0702
Version:2.1.0
Name:CycleType
Title:cycleType
Status:Active
Content:All the concepts defined by the code system are included in the code system resource
Definition:

Code system of concepts specifying the type of cycle that is being executed. A cycle type is a specific sterilization method used for a specific type of supply item. Used in HL7 Version 2.x messaging in the SCD segment.

Publisher:HL7, Inc
Committee:Orders and Observations
OID:2.16.840.1.113883.18.387 (for OID based terminology systems)
Content Mode:Complete
Value Set:http://terminology.hl7.org/ValueSet/v2-0702 ( is the value set for all codes in this code system)
Copyright:

Copyright HL7. Licensed under creative commons public domain

Source Resource:XML / JSON / Turtle

This Code system is referenced in the content logical definition of the following value sets:

cycleType

Code system of concepts specifying the type of cycle that is being executed. A cycle type is a specific sterilization method used for a specific type of supply item. Used in HL7 Version 2.x messaging in the SCD segment.

Copyright Statement: Copyright HL7. Licensed under creative commons public domain

Properties

CodeURLDescriptionType
statushttp://terminology.hl7.org/CodeSystem/utg-concept-properties#statusStatus of the conceptcode
deprecatedhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecatedVersion of HL7 in which the code was deprecatedcode
v2-concCommenthttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentV2 Concept Commentstring
v2-concCommentAsPubhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPubV2 Concept Comment As Publishedstring

This code system http://terminology.hl7.org/CodeSystem/v2-0702 defines the following codes:

CodeDisplayDefinitionV2 Table StatusV2 Concept CommentV2 Concept Comment As Published
FLS FlashFlashAUsed to quickly sterilize instruments that were dropped during surgery.Used to quickly sterilize instruments that were dropped during surgery.
PRV PrevacPrevacAA prevac cycle is vacuum assisted.A prevac cycle is vacuum assisted.
GRV GravityGravityAA gravity cycle is executed at atmospheric pressure.A gravity cycle is executed at atmospheric pressure.
LQD LiquidLiquidAA cycle specific to sterilizing liquids.A cycle specific to sterilizing liquids.
EXP ExpressExpressAAn express cycle is similar to a flash cycle but the supply item is wrapped.An express cycle is similar to a flash cycle but the supply item is wrapped.
DRT DartDartAA dart cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum.A dart cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum.
DRW Dart Warm-up CycleDart Warm-up CycleAA dart warm-up cycle is used to bring the sterilizer chamber up to operating temperature in order to run a dart test cycle.A dart warm-up cycle is used to bring the sterilizer chamber up to operating temperature in order to run a dart test cycle.
THR ThermalThermalA
ISO IsothermalIsothermalA
BWD Bowie-Dick TestBowie-Dick TestAA Bowie-Dick test cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum.A Bowie-Dick test cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum.
LKT Leak TestLeak TestAA leak test cycle tests the integrity of the sterilizer chamber to hold a vacuum over a specific period of time.A leak test cycle tests the integrity of the sterilizer chamber to hold a vacuum over a specific period of time.
WFP Wrap/Steam Flush Pressure Pulse (Wrap/SFPP)Wrap/Steam Flush Pressure Pulse (Wrap/SFPP)AA Wrap/SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is unwrapped.A Wrap/SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is unwrapped.
SFP Steam Flush Pressure PulseSteam Flush Pressure PulseAAn SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is wrapped.An SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is wrapped.
CMW Chemical WashChemical WashAA chemical wash cycle.A chemical wash cycle.
PEA Peracetic AcidPeracetic AcidAA peracetic acid cycle.A peracetic acid cycle.
EOH EO High TemperatureEO High TemperatureA
EOL EO Low TemperatureEO Low TemperatureA
CRT Cart WashCart WashA
UTL Utensil WashUtensil WashA
IST Instrument WashInstrument WashA
GLS GlasswareGlasswareA
PLA Plastic Goods WashPlastic Goods WashA
ANR Anesthesia/RespiratoryAnesthesia/RespiratoryASpecial Wash cycleSpecial Wash cycle
GTL GentleGentleA
OPW Optional WashOptional WashAAny Optional Wash cycleAny Optional Wash cycle
BDP BedpansBedpansA
TRB Tray/BasinTray/BasinA
GNP Gen. PurposeGen. PurposeA
COD CodeCodeA
RNS RinseRinseA
2RS Second RinseSecond RinseA
DEC DecontaminationDecontaminationA