This page is part of the HL7 Terminology (v1.0.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions
Source view
{ "resourceType" : "CodeSystem", "id" : "v2-0299", "text" : { "status" : "generated", "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2>encoding</h2><div><p>HL7-defined code system of concept identifying the type of encoding used to represent successive octets of binary data as displayable ASCII characters. These are defined by IETF; more information may be found at https://www.ietf.org/rfc/rfc1521.txt. Used in HL7 Version 2.x messaging in the ED datatypes.</p>\n</div><p><b>Copyright Statement:</b> Copyright HL7. Licensed under creative commons public domain</p><p><b>Properties</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>URL</b></td><td><b>Description</b></td><td><b>Type</b></td></tr><tr><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>Status of the concept</td><td>code</td></tr><tr><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>Version of HL7 in which the code was deprecated</td><td>code</td></tr><tr><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>V2 Concept Comment</td><td>string</td></tr><tr><td>v2-concCommentAsPub</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub</td><td>V2 Concept Comment As Published</td><td>string</td></tr></table><p>This code system http://terminology.hl7.org/CodeSystem/v2-0299 defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Table Status</b></td><td><b>V2 Concept Comment</b></td><td><b>V2 Concept Comment As Published</b></td></tr><tr><td style=\"white-space:nowrap\">A<a name=\"v2-0299-A\"> </a></td><td>No encoding - data are displayable ASCII characters.</td><td>No encoding - data are displayable ASCII characters.</td><td>A</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">Hex<a name=\"v2-0299-Hex\"> </a></td><td>Hexadecimal encoding - consecutive pairs of hexadecimal digits represent consecutive single octets.</td><td>Hexadecimal encoding - consecutive pairs of hexadecimal digits represent consecutive single octets.</td><td>A</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">Base64<a name=\"v2-0299-Base64\"> </a></td><td>Encoding as defined by MIME (Multipurpose Internet Mail Extensions) standard RFC 1521. Four consecutive ASCII characters represent three consecutive octets of binary data. Base64 utilizes a 65-character subset of US-ASCII, consisting of both the upper and</td><td>Encoding as defined by MIME (Multipurpose Internet Mail Extensions) standard RFC 1521. Four consecutive ASCII characters represent three consecutive octets of binary data. Base64 utilizes a 65-character subset of US-ASCII, consisting of both the upper and lower case alphabetic characters, digits “0” through “9”, “+”, “/”, and “=”.</td><td>A</td><td>The Request For Comment (RFC) 1521 standard is available at: http://www.ietf.org/rfc/rfc1521.txt</td><td>The Request For Comment (RFC) 1521 standard is available at: http://www.ietf.org/rfc/rfc1521.txt</td></tr></table><p><b>Additional Language Displays</b></p><table class=\"codes\"><tr><td><b>Code</b></td><td><b>Deutsch (German, de)</b></td></tr><tr><td>A</td><td>keine Kodierung</td></tr><tr><td>Hex</td><td></td></tr><tr><td>Base64</td><td></td></tr></table></div>" }, "url" : "http://terminology.hl7.org/CodeSystem/v2-0299", "identifier" : [ { "system" : "urn:ietf:rfc:3986", "value" : "urn:oid:2.16.840.1.113883.18.185" } ], "version" : "2.1.0", "name" : "Encoding", "title" : "encoding", "status" : "active", "experimental" : false, "date" : "2019-12-01T00:00:00-05:00", "publisher" : "HL7, Inc", "contact" : [ { "telecom" : [ { "system" : "url", "value" : "http://www.hl7.org/" } ] } ], "description" : "HL7-defined code system of concept identifying the type of encoding used to represent successive octets of binary data as displayable ASCII characters. These are defined by IETF; more information may be found at https://www.ietf.org/rfc/rfc1521.txt. Used in HL7 Version 2.x messaging in the ED datatypes.", "purpose" : "Underlying Master Code System for V2 table 0299 (Encoding)", "copyright" : "Copyright HL7. Licensed under creative commons public domain", "caseSensitive" : true, "valueSet" : "http://terminology.hl7.org/ValueSet/v2-0299", "hierarchyMeaning" : "is-a", "compositional" : false, "versionNeeded" : false, "content" : "complete", "property" : [ { "code" : "status", "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status", "description" : "Status of the concept", "type" : "code" }, { "code" : "deprecated", "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated", "description" : "Version of HL7 in which the code was deprecated", "type" : "code" }, { "code" : "v2-concComment", "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment", "description" : "V2 Concept Comment", "type" : "string" }, { "code" : "v2-concCommentAsPub", "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub", "description" : "V2 Concept Comment As Published", "type" : "string" } ], "concept" : [ { "id" : "2974", "code" : "A", "display" : "No encoding - data are displayable ASCII characters.", "definition" : "No encoding - data are displayable ASCII characters.", "designation" : [ { "language" : "de", "use" : { "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra", "code" : "preferredForLanguage" }, "value" : "keine Kodierung" } ], "property" : [ { "code" : "status", "valueCode" : "A" } ] }, { "id" : "2975", "code" : "Hex", "display" : "Hexadecimal encoding - consecutive pairs of hexadecimal digits represent consecutive single octets.", "definition" : "Hexadecimal encoding - consecutive pairs of hexadecimal digits represent consecutive single octets.", "property" : [ { "code" : "status", "valueCode" : "A" } ] }, { "id" : "2976", "code" : "Base64", "display" : "Encoding as defined by MIME (Multipurpose Internet Mail Extensions) standard RFC 1521. Four consecutive ASCII characters represent three consecutive octets of binary data. Base64 utilizes a 65-character subset of US-ASCII, consisting of both the upper and", "definition" : "Encoding as defined by MIME (Multipurpose Internet Mail Extensions) standard RFC 1521. Four consecutive ASCII characters represent three consecutive octets of binary data. Base64 utilizes a 65-character subset of US-ASCII, consisting of both the upper and lower case alphabetic characters, digits “0” through “9”, “+”, “/”, and “=”.", "property" : [ { "code" : "v2-concComment", "valueString" : "The Request For Comment (RFC) 1521 standard is available at: http://www.ietf.org/rfc/rfc1521.txt" }, { "code" : "v2-concCommentAsPub", "valueString" : "The Request For Comment (RFC) 1521 standard is available at: http://www.ietf.org/rfc/rfc1521.txt" }, { "code" : "status", "valueCode" : "A" } ] } ] }