HL7 Terminology
1.0.0 - Publication

This page is part of the HL7 Terminology (v1.0.0: Release) based on FHIR R4. The current version which supercedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions

StandardsStatus

Summary

Defining URL:http://terminology.hl7.org/CodeSystem/standards-status
Version:4.2.0
Name:StandardsStatus
Title:StandardsStatus
Status:draft
Content:All the concepts defined by the code system are included in the code system resource
Definition:

HL7 Ballot/Standards status of artifact.

Publisher:HL7 (FHIR Project)
OID:2.16.840.1.113883.4.642.1.1366 (for OID based terminology systems)
Content Mode:Complete
Value Set:http://terminology.hl7.org/ValueSet/standards-status ( is the value set for all codes in this code system)
Source Resource:XML / JSON / Turtle

This Code system is referenced in the content logical definition of the following value sets:

StandardsStatus

HL7 Ballot/Standards status of artifact.

This code system http://terminology.hl7.org/CodeSystem/standards-status defines the following codes:

CodeDisplayDefinition
draft DraftThis portion of the specification is not considered to be complete enough or sufficiently reviewed to be safe for implementation. It may have known issues or still be in the "in development" stage. It is included in the publication as a place-holder, to solicit feedback from the implementation community and/or to give implementers some insight as to functionality likely to be included in future versions of the specification. Content at this level should only be implemented by the brave or desperate and is very much "use at your own risk". The content that is Draft that will usually be elevated to Trial Use once review and correction is complete after it has been subjected to ballot.
normative NormativeThis content has been subject to review and production implementation in a wide variety of environments. The content is considered to be stable and has been 'locked', subjecting it to FHIR Inter-version Compatibility Rules. While changes are possible, they are expected to be infrequent and are tightly constrained. Compatibility Rules.
trial-use Trial-UseThis content has been well reviewed and is considered by the authors to be ready for use in production systems. It has been subjected to ballot and approved as an official standard. However, it has not yet seen widespread use in production across the full spectrum of environments it is intended to be used in. In some cases, there may be documented known issues that require implementation experience to determine appropriate resolutions for. Future versions of FHIR may make significant changes to Trial Use content that are not compatible with previously published content.
informative InformativeThis portion of the specification is provided for implementer assistance, and does not make rules that implementers are required to follow. Typical examples of this content in the FHIR specification are tables of contents, registries, examples, and implementer advice.
deprecated DeprecatedThis portion of the specification is provided for implementer assistance, and does not make rules that implementers are required to follow. Typical examples of this content in the FHIR specification are tables of contents, registries, examples, and implementer advice.
external ExternalThis is content that is managed outside the FHIR Specification, but included for implementer convenience.

History

DateActionAuthorCustodianComment
2020-05-06reviseTed KleinVocabulary WGMigrated to the UTG maintenance environment and publishing tooling.